Key result
Wavelet entropy effectively quantified the suppression of ventricular activity from electrocardiograms in atrial fibrillation using both synthesized and patient recordings.
Wavelet entropy provides a novel and effective method for quantifying ventricular beat suppression in ECGs of patients with atrial fibrillation.
A novel method of quantifying the effectiveness of the suppression of ventricular activity from electrocardiograms (ECGs) in atrial fibrillation is proposed. The temporal distribution of the energy of wavelet coefficients is quantified by wavelet entropy at each ventricular beat. More effective ventricular activity suppression yields increased entropies at scales dominated by the ventricular and atrial components of the ECG. Two studies are undertaken to demonstrate the efficacy of the method: first, using synthesised ECGs with controlled levels of residual ventricular activity, and second, using patient recordings with ventricular activity suppressed by an average beat template subtraction algorithm. In both cases wavelet entropy is shown to be a good measure of the effectiveness of ventricular beat suppression.
No takes yet. Share an insight, caveat, or question.
Philip Langley (2015) studied Atrial Fibrillation. Wavelet entropy was evaluated on Effectiveness of ventricular beat suppression. Wavelet entropy effectively quantified the suppression of ventricular activity from electrocardiograms in atrial fibrillation using both synthesized and patient recordings.