Key result
Prior cut and sew surgical maze resulted in 94% of pulmonary veins being isolated compared to only 26% for non-cut and sew maze among patients undergoing catheter ablation for failed maze.
Why the study?
To compare findings during catheter ablation for AF and/or atrial flutter in patients with a failed cut and sew versus non-cut and sew surgical maze.
Does a cut and sew surgical maze improve durable pulmonary vein isolation compared to a non-cut and sew maze in patients with recurrent atrial arrhythmias?
Observational (n=35)
No
Does a cut and sew surgical maze improve durable pulmonary vein isolation compared to a non-cut and sew maze in patients with recurrent atrial arrhythmias?
In patients requiring catheter ablation for failed surgical maze, the classic cut-and-sew technique provides significantly more durable pulmonary vein isolation than non-cut-and-sew approaches.
Answers are grounded in this paper and cite their sources.
Supports prioritizing cut-and-sew for durable PVI in surgical maze; leaves open impact on arrhythmia recurrence after redo ablation.
PURPOSE: To compare findings in patients undergoing atrial fibrillation(AF) and/or atrial flutter(AFl) ablation after failed cut and sew (CS) vs. non-cut and sew (NCS) surgical maze. METHODS: We compared 10 patients with prior CS to 25 with prior NCS maze undergoing catheter ablation after failed maze. RESULTS: Patient demographics: Age 68.3 ± 8.7 CS vs. 68.2 ± 9.2 NCS(P = 0.977), male 70% CS vs. 72% NCS(P = 1.000), LA size 5.11 ± 0.60 cm CS vs. 4.54 ± 0.92 cm NCS(P = 0.096), sternotomy 100% CS vs. 64% of NCS(P = 0.036). Concomitant heart surgery in 100% CS and 68% NCS(P = 0.073). NCS used radiofrequency 84%, cryoablation 8%, microwave 4%, and ultrasound 4%. All maze operations targeted pulmonary vein (PV) isolation. The maze also targeted the mitral isthmus 100% CS vs. 36% NCS(P = 0.001) and the tricuspid isthmus 90% CS vs. 40% NCS (P = 0.018). Maze failure arrhythmia mechanism was AF 0% CS and 56% NCS (P = 0.0006). Nine CS pts failed for AFl and 1 for RA tachycardia. For NCS pts, 11 failed for AFl. CS isolated 94% of PVs and NCS isolated only 26% of PVs (P < 0.0005). At EPS, clinical and induced arrhythmias were ablated and non-isolated PVs were isolated. After final ablation, arrhythmia-free rates were 60% for CS and 52% for NCS (P = 0.723) after 2.99 ± 2.35 years. CONCLUSIONS: After failed surgical maze, CS isolated nearly all PVs and NCS never isolated all PVs and the clinical rhythm was more frequently AF for NCS and AFl for CS. CS remains the surgical gold standard for durable PV isolation.
No takes yet. Share an insight, caveat, or question.
Winkle et al. (2019) conducted an observational in Recurrent atrial arrhythmias after failed surgical maze operation (n=35). Cut and sew (CS) surgical maze vs. Non-cut and sew (NCS) surgical maze was evaluated on Pulmonary vein isolation rate (p=<0.0005). Prior cut and sew surgical maze resulted in 94% of pulmonary veins being isolated compared to only 26% for non-cut and sew maze among patients undergoing catheter ablation for failed maze.
Synapse has enriched 10 related papers. Consider them for comparative context: