Key result
Increased operator experience with circular multipolar phased radiofrequency ablation reduced fluoroscopy times and RF applications, but did not improve 12-month arrhythmia-free survival.
Why the study?
Does operator experience (learning curve) improve procedural parameters and clinical outcomes in patients undergoing circular multipolar phased radiofrequency ablation for atrial fibrillation?
Observational (n=132)
No
Does operator experience (learning curve) improve procedural parameters and clinical outcomes in patients undergoing circular multipolar phased radiofrequency ablation for atrial fibrillation?
A learning curve exists for procedural efficiency (fluoroscopy time and RF applications) in circular multipolar phased RF ablation, but acute success and 12-month arrhythmia-free survival are achieved early in the operator's experience.
Answers are grounded in this paper and cite their sources.
Supports early competence for outcomes despite efficiency gains; leaves open randomized confirmation of learning effects.
BACKGROUND: Although atrial fibrillation (AF) ablation is considered a technically challenging procedure, studies on the learning curve of different pulmonary vein isolation (PVI) techniques are limited. We investigated the time-dependent changes in procedural parameters, complication rates, and in the 1-year clinical outcome during our initial experience with circular multipolar phased radiofrequency (RF) ablation. METHODS AND RESULTS: The first 132 consecutive patients (40 female; age: 56.6 ± 10.4 years) who underwent PVI with phased RF ablation for paroxysmal or persistent AF at our center were included in the study. Procedural parameters and atrial arrhythmia-free survival were compared in the first, second and third group of 44 successive patients. All pulmonary veins were successfully isolated in 44 (100%), 41 (93.8%) and 42 (95.5%) patients in Tierce 1, 2 and 3, respectively (p = 0.233). The number of RF applications (per vein) required for isolation and fluoroscopy times demonstrated a significant decrease with experience, and a trend towards lower procedure times in Tierces 2 and 3 was also observed. Atrial arrhythmia-free survival rates at 12 months postablation were 68.18%, 75%, and 70.75% in Tierce 1, Tierce 2 and Tierce 3, respectively (p = 0.772). Pericardial tamponade requiring percutaneous subxiphoid drainage occurred in 1 patient (Tierce 3) as the only significant procedural complication. CONCLUSIONS: A learning curve effect was demonstrated in fluoroscopy times and in the number of RF applications but not in the acute success and in the long-term arrhythmia-free survival with circular multipolar RF ablations.
No takes yet. Share an insight, caveat, or question.
Martirosyan et al. (2015) conducted an observational in Paroxysmal or persistent atrial fibrillation (n=132). Operator experience (successive patient tierces) vs. Initial patient tierce was evaluated on Atrial arrhythmia-free survival at 12 months (HR 0.898, 95% CI 0.383-2.106, p=0.805). Increased operator experience with circular multipolar phased radiofrequency ablation reduced fluoroscopy times and RF applications, but did not improve 12-month arrhythmia-free survival.