Key result
Cryoablation linked to ~2-fold higher rate of atrial septal defect vs RF ablation.
Why the study?
The study was conducted to compare the incidence of septal defect in patients with AF who underwent radiofrequency ablation versus cryoablation.
Does cryoablation increase the incidence of iatrogenic atrial septal defect compared to radiofrequency ablation in patients with atrial fibrillation?
Cohort (n=293)
No
Does cryoablation increase the incidence of iatrogenic atrial septal defect compared to radiofrequency ablation in patients with atrial fibrillation?
Cryoablation is associated with a significantly higher risk of persistent iatrogenic atrial septal defect compared to radiofrequency ablation, which in turn increases the risk of atrial fibrillation recurrence.
Answers are grounded in this paper and cite their sources.
Cryoablation was associated with higher iatrogenic ASD incidence; leaves open whether this influences AF recurrence or ablation technique selection.
OBJECTIVE: The present study was to compare the incidence of septal defect (SD) in patients with atrial fibrillation (AF) who received radiofrequency ablation or cryoablation. METHODS: A total of 293 AF patients were performed with radiofrequency ablation and cryoablation. Cardiac ultrasonography was performed to calculate left atrial diameter (LAD), left atrial ejection fraction (LAEF%), strain rate (SR), left ventricular systolic (SRs), left ventricular diastolic (SRe), and left atrial systole (SRa) before surgery, 3 months and 1 year after surgery. The patients were followed up to observe statin and angiotensin-converting enzyme inhibitor (ACEI)/angiotensin receptor blocker (ARB) medication, AF recurrence, 6-min walk test, stroke, any symptoms caused by arrhythmia, and re-hospitalization. RESULTS: The levels of LAD and SD were higher, while SRe and SRa were lower in the cryoablation group in the comparison with the radiofrequency ablation group after surgery (P<0.05). LAEF was lower in the cryoablation group than the radiofrequency ablation group after 3 months (P<0.05). After 1-year follow-up, no right-to-left shunt occurred in all patients with SD. The AF recurrence rate in SD group was higher than that in the normal group (P<0.05). The use of statin and the application of ACEI/ARB were protective factors, whereas hypertension, LAD, left atrial operation time, and surgical plan were risk factors. CONCLUSION: SD affects left atrial function and increases the risk of AF recurrence. Hypertension, LAD, and left atrial operation time are risk factors for SD, whereas statin and ACEI/ARB drugs can reduce SD.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2020) conducted a cohort in Atrial Fibrillation (n=293). Cryoablation vs. Radiofrequency ablation was evaluated on Incidence of atrial septal defect at 3 months (p=0.006). Cryoablation resulted in a higher incidence of atrial septal defect at 3 months compared to radiofrequency ablation.