Why the study?
Does 24-hour ambulatory blood pressure measurement improve pharmacokinetic-pharmacodynamic modeling compared to manual blood pressure measurement in hypertensive patients receiving moxonidine?
Does 24-hour ambulatory blood pressure measurement improve pharmacokinetic-pharmacodynamic modeling compared to manual blood pressure measurement in hypertensive patients receiving moxonidine?
24-hour ambulatory blood pressure monitoring provides more precise estimates of interindividual variability in pharmacodynamic profiles compared to manual measurements.
Answers are grounded in this paper and cite their sources.
24-hour ABPM enhances precision of pharmacodynamic variability estimates in hypertension modeling; extends PK-PD methods beyond manual BP in RCTs.
OBJECTIVES: To compare the results of the pharmacokinetic-pharmacodynamic analyses of 24-hour ambulatory blood pressure measurements and manual blood pressure data in patients receiving moxonidine. METHODS: 32 patients with borderline to mild-to-moderate hypertension were enrolled in a double-blind, placebo-controlled phase II study. After receiving placebo for 1 week (run-in phase), the patients were randomly allocated to the placebo or the 0.6-, 0.9-, or 1.2-mg dose groups. Placebo and moxonidine were administered once daily for 1 week (drug-treatment phase). Four 24-hour ambulatory blood pressure measurement profiles were obtained for each individual. Plasma samples (n = 9) and four measurements of manual blood pressure were taken at the start and end of the drug-treatment phase. Two additional manual blood pressure measurements were taken during the run-in and drug-treatment phases. RESULTS: Pharmacokinetics was described by a one-compartment model. For the 24-hour ambulatory blood pressure measurements, baseline circadian patterns were described with a two-cosine function model that included interindividual and interoccasion variability. Pharmacodynamics was described with use of an effect-compartment model [k(e0) = 0.37 (1/h)] and an Emax model. For diastolic blood pressure the maximum drug-induced decrease (Emax) was 30.9 mm Hg and the steady-state plasma drug concentration eliciting half of maximum effect (C50) was 1.33 microg/L. Interindividual variability was estimated for ke0 (24.8%) and Emax (33.3%). For the manual blood pressure measurements, data was described by a time-invariant baseline model combined with an effect-compartment model and an Emax model. Mean population estimates were in agreement with those obtained during the analysis of 24-hour ambulatory blood pressure measurements. However, interindividual variability could be estimated for the baseline parameter only. CONCLUSIONS: Although similar typical population estimates for the drug action-related parameters were obtained with use of manual blood pressure data and 24-hour ambulatory blood pressure measurements, the latter allowed for a more detailed description of the individual pharmacodynamic profiles because interindividual variability in pharmacodynamic parameters could be estimated together with increased precision in parameter estimates.
No takes yet. Share an insight, caveat, or question.
Iñaki F. Trocóniz (2000) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: