Key result
Increasing distance from pacing sites led to significant attenuation of unipolar electrogram amplitudes (V-P attenuated by 7.0±0.5% per cm, p<0.01), whereas bipolar electrogram attenuation was insignificant.
Why the study?
Does propagation distance and stimulation depth affect unipolar and bipolar electrogram amplitude and transmural gradients in normal sheep hearts?
Does propagation distance and stimulation depth affect unipolar and bipolar electrogram amplitude and transmural gradients in normal sheep hearts?
Effect estimate: 7.0±0.5% attenuation per cm
p-value: p=<0.01
Electrogram amplitude is inversely proportional to propagation distance for unipolar modalities only, and conduction propagates preferentially via the epicardium during stimulation.
Unipolar amplitude attenuation with distance in sheep hearts warrants caution in experimental mapping; leaves open translation to clinical electroanatomic systems.
PURPOSE: Unipolar (UE) and bipolar electrograms (BE) are utilized to identify arrhythmogenic substrate. We quantified the effect of increasing distance from the source of propagation on local electrogram amplitude; and determined if transmural electrophysiological gradients exist with respect to propagation and stimulation depth. METHODS: Mapping was performed on 5 sheep. Deployment of >50 quadripolar transmural needles in the LV were located in Cartesian space using Ensite. Contact electrograms from all needles were recorded during multisite bipolar pacing from epicardial then endocardial electrodes. Analysis was performed to determine stimulus distance to local activation time, peak negative amplitude (V-P), and peak-peak amplitude (VP-P) for (1) unfiltered UE, and (2) unfiltered and 30 Hz high-pass filtered BEs. Each sheep was analysed using repeated ANOVA. RESULTS: Increasing distance from the pacing sites led to significant (p<0.01) attenuation of UEs (V-P = 7.0±0.5%; VP-P = 5.4±0.3% per cm). Attenuation of BE with distance was insignificant (Vp-p unfiltered = 2.2±0.5%; filtered = 1.7±1.4% per cm). Independent of pacing depth, significant (p<0.01) transmural electrophysiological gradients were observed, with highest amplitude occurring at epicardial layers for UE and endocardial layers for BE. Furthermore, during pacing, propagation was earlier at the epicardium than endocardial layer by 1.6±2.0 ms (UE) and 1.4±2.8 ms (BE) (all p>0.01) during endocardial stimulation, and 2.3±2.4 ms (UE) and 1.8±3.7 ms (BE) during epicardal stimulation (all p<0.01). CONCLUSIONS: Electrogram amplitude is inversely proportional to propagation distance for unipolar modalities only, which affected V-P>VP-P. Conduction propagates preferentially via the epicardium during stimulation and is believed to contribute to a transmural amplitude gradient.
No takes yet. Share an insight, caveat, or question.
Pouliopoulos et al. (2014) studied Normal heart electrophysiology (n=5). Multisite bipolar pacing vs. Increasing distance from pacing site was evaluated on Attenuation of unipolar electrogram amplitude (V-P) with increasing distance from pacing site (7.0±0.5% attenuation per cm, p=<0.01). Increasing distance from pacing sites led to significant attenuation of unipolar electrogram amplitudes (V-P attenuated by 7.0±0.5% per cm, p<0.01), whereas bipolar electrogram attenuation was insignificant.