Key result
Real-life warfarin anticoagulation was poor, with only 50.1% of all INRs within the target range and only 23.0% of patients achieving adequate anticoagulation.
Why the study?
The quality of real-life warfarin anticoagulation in patients requiring chronic thromboprophylaxis in a southern Croatian county needed to be assessed.
Observational (n=2,240)
No
Real-world warfarin anticoagulation quality in a Croatian county is poor, with only 23% of patients achieving adequate time in therapeutic range, highlighting the need for improved management or alternative therapies.
Answers are grounded in this paper and cite their sources.
Suboptimal real-world warfarin TTR should not yet change practice; leaves open whether alternatives or monitoring improve outcomes.
AIM: To assess the quality of real-life warfarin anticoagulation in patients requiring chronic thromboprophylaxis in a southern Croatian county. METHODS: We retrospectively analyzed international normalized ratio (INR) values determined over one year (2016-2017) at the Zadar County General Hospital in warfarin-treated patients requiring chronic thromboprophylaxis. The values represent 83.0% of all INRs and were determined in 84.0% of all warfarin-treated patients in the county during the observed period. RESULTS: Overall 31162 INRs were taken from 3697 patients, 2240 of whom (20 851 INRs, 3-56 per patient, median 9) were referred with diagnoses requiring chronic thromboprophylaxis: mainly atrial fibrillation/flutter (n=1508, 14902 INRs) but also cardiac implants, valvular disease, severe heart failure, and cerebrovascular disease ("other", n=732, 5949 INRs). Only 50.1% of all INRs were within the target range, 2.0-3.5, while 43.6% were <2.0, and 6.3% were >3.5. Median crude individual proportion of INRs within the range was 50.0%, while it was 42.0% for INRs <2.0. Only 23.0% of the patients had ≥70% of the INRs within the target range (adequately anticoagulated), while 35.5% had ≤33.3% of the INRs within the range. Conversely, 66.5% of the patients had ≥33.3% INRs <2.0. Adjusted probability of adequate anticoagulation in atrial fibrillation/flutter patients was consistently 25.5% to 27.7%, regardless of the number of determined INRs, while in patients with other conditions it increased from 9.5% to 25.2% with a higher number of INRs. CONCLUSION: The achieved level of warfarin anticoagulation in this real-life setting is far below what is needed for effective long-term thromboprophylaxis.
No takes yet. Share an insight, caveat, or question.
Knežević et al. (2019) conducted an observational in Chronic thromboprophylaxis (mainly atrial fibrillation/flutter) (n=2,240). Warfarin was evaluated on Proportion of INRs within the target range (2.0-3.5). Real-life warfarin anticoagulation was poor, with only 50.1% of all INRs within the target range and only 23.0% of patients achieving adequate anticoagulation.
Synapse has enriched 10 related papers. Consider them for comparative context: