Key result
L-type calcium current block reduced the frequency of re-entry by 12.2%, 6.9%, and 4.2% in hiPSC-CM cultures, virtual hiPSC-CM, and adult ventricular cardiomyocyte tissues, respectively.
Why the study?
The high incidence of cardiac arrhythmias underlines the need to assess pharmacological therapies using integrated in silico experiments and human induced pluripotent stem cell-derived cardiomyocytes.
Does ICaL block reduce re-entry frequency and vulnerable window in hiPSC-CM and hAdultV-CM tissues?
Does ICaL block reduce re-entry frequency and vulnerable window in hiPSC-CM and hAdultV-CM tissues?
ICaL block reduces re-entry frequency and shortens the vulnerable window in hiPSC-CMs, demonstrating that virtual hiPSC-CM tissues are suitable for assessing cardiac drug efficacy.
Answers are grounded in this paper and cite their sources.
Does not support clinical use of ICaL block for re-entry; extends validation of virtual hiPSC-CM models for preclinical testing.
The high incidence of cardiac arrythmias underlines the need for the assessment of pharmacological therapies. In this field of drug efficacy, as in the field of drug safety highlighted by the Comprehensive in Vitro Proarrhythmia Assay initiative, new pillars for research have become crucial: firstly, the integration of in-silico experiments, and secondly the evaluation of fully integrated biological systems, such as human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs). In this study, we therefore aimed to combine in-vitro experiments and in-silico simulations to evaluate the antiarrhythmic effect of L-type calcium current (ICaL) block in hiPSC-CMs. For this, hiPSC-CM preparations were cultured and an equivalent virtual tissue was modeled. Re-entry patterns of electrical activation were induced and several biomarkers were obtained before and after ICaL block. The virtual hiPSC-CM simulations were also reproduced using a tissue composed of adult ventricular cardiomyocytes (hAdultV-CMs). The analysis of phases, currents and safety factor for propagation showed an increased size of the re-entry core when ICaL was blocked as a result of depressed cellular excitability. The bigger wavefront curvature yielded reductions of 12.2%, 6.9%, and 4.2% in the frequency of the re-entry for hiPSC-CM cultures, virtual hiPSC-CM, and hAdultV-CM tissues, respectively. Furthermore, ICaL block led to a 47.8% shortening of the vulnerable window for re-entry in the virtual hiPSC-CM tissue and to re-entry vanishment in hAdultV-CM tissue. The consistent behavior between in-vitro and in-silico hiPSC-CMs and between in-silico hiPSC-CMs and hAdultV-CMs evidences that virtual hiPSC-CM tissues are suitable for assessing cardiac efficacy, as done in the present study through the analysis of ICaL block.
No takes yet. Share an insight, caveat, or question.
Dasí et al. (2021) studied Cardiac arrhythmias. L-type calcium current (ICaL) block vs. Before ICaL block was evaluated on Re-entry frequency and vulnerable window for re-entry. L-type calcium current block reduced the frequency of re-entry by 12.2%, 6.9%, and 4.2% in hiPSC-CM cultures, virtual hiPSC-CM, and adult ventricular cardiomyocyte tissues, respectively.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: