Key result
Chair-based cuffless blood pressure monitor meets AAMI accuracy standards with mean error under ~0.1 mmHg.
Why the study?
Existing cuffless blood pressure monitoring methods require intentional sensor contact and suffer from reduced accuracy when photoplethysmogram or electrocardiogram signal quality drops.
Does a chair-based unconstrained cuffless blood pressure monitoring system accurately estimate resting blood pressure in healthy normotensive adults?
Cross-Sectional (n=30)
No
Does a chair-based unconstrained cuffless blood pressure monitoring system accurately estimate resting blood pressure in healthy normotensive adults?
A nonintrusive chair-based monitoring system using ballistocardiogram signals and neural networks can accurately estimate resting blood pressure in healthy adults within standard protocol margins.
Answers are grounded in this paper and cite their sources.
Supports nonintrusive BP monitoring in normotensive adults; leaves open validation in hypertension and ambulatory settings.
Hypertension is a well-known chronic disease that causes complications such as cardiovascular diseases or stroke, and thus needs to be continuously managed by using a simple system for measuring blood pressure. The existing method for measuring blood pressure uses a wrapping cuff, which makes measuring difficult for patients. To address this problem, cuffless blood pressure measurement methods that detect the peak pressure via signals measured using photoplethysmogram (PPG) and electrocardiogram (ECG) sensors and use it to calculate the pulse transit time (PTT) or pulse wave velocity (PWV) have been studied. However, a drawback of these methods is that a user must be able to recognize and establish contact with the sensor. Furthermore, the peak of the PPG or ECG cannot be detected if the signal quality drops, leading to a decrease in accuracy. In this study, a chair-type system that can monitor blood pressure using polyvinylidene fluoride (PVDF) films in a nonintrusive manner to users was developed. The proposed method also uses instantaneous phase difference (IPD) instead of PTT as the feature value for estimating blood pressure. Experiments were conducted using a blood pressure estimation model created via an artificial neural network (ANN), which showed that IPD could estimate more accurate readings of blood pressure compared to PTT, thus demonstrating the possibility of a nonintrusive blood pressure monitoring system.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2019) conducted a cross-sectional in Normotension (Healthy volunteers) (n=30). Chair-based unconstrained cuffless blood pressure monitoring system vs. Commercial cuff-type blood pressure monitor (Omron HEM-7121) was evaluated on Mean error and standard deviation of estimated blood pressure compared to a commercial cuff-based monitor (Systolic BP mean error 0.01 mmHg (SD 6.7); Diastolic BP mean error 0.05 mmHg (SD 5.8)). The chair-based cuffless monitoring system estimated systolic and diastolic blood pressures with mean errors of 0.01 mmHg and 0.05 mmHg respectively, meeting AAMI accuracy criteria.