PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 1, 1967Circulation Research403 citationsOpen Access

Improved Assay Methods for Renin "Concentration" and "Activity" in Human Plasma

View Full Paper
SSSandford L. Skinner

Key Result

Simplified assay methods for human plasma renin concentration and activity based on renin substrate denaturation demonstrated complete renin recovery and linear reaction rates suitable for routine use.

Structured PICO

P
Population
Human plasma samples
I
Intervention
Simplified assay methods for plasma renin concentration (PRC) and activity (PRA) based on denaturation of renin substrate
O
Outcome
Measurement of plasma renin concentration and activitysurrogate

The study describes simplified, reliable assay methods for measuring plasma renin concentration and activity that avoid separation and concentration steps.

Abstract

Simplified methods are described for the measurement of human plasma renin "concentration" (PRC) and "activity" (PRA) based on the denaturation of renin substrate in which separation and concentration steps are avoided and recovery of renin is complete. In the PRA method effective inhibition of angiotensinase is achieved by warming plasma at pH 4.5 with EDTA followed by dialysis to pH 7.5. Neither renin nor renin substrate is affected by this treatment. In the PRC method, renin substrate is selectively denatured by warming at pH 3.3. After dialysis to pH 7.5 and addition of a standard substrate prepared from nephrectomized sheep, incubation results in a linear increase of pressor material which is assayed without extraction on rat blood pressure against synthetic angiotensin. Specificity is established by nephrectomy and immunological studies. The linear relationship between plasma renin concentration and reaction rate contrasted with the nonlinearity observed with renal renin. The systems are suitable for routine diagnostic use.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Sandford L. Skinner (1967) studied this question. Simplified assay methods for plasma renin concentration and activity was evaluated on Measurement of human plasma renin concentration and activity. Simplified assay methods for human plasma renin concentration and activity based on renin substrate denaturation demonstrated complete renin recovery and linear reaction rates suitable for routine use.