Why the study?
MRI-derived fat fraction and R2* data previously used to characterize carotid plaque features relied on time-consuming manual analyses.
Does automated segmentation of the carotid artery using MRI provide comparable vessel wall composition data to manual analysis in subjects from the SCAPIS cohort?
Does automated segmentation of the carotid artery using MRI provide comparable vessel wall composition data to manual analysis in subjects from the SCAPIS cohort?
Automated MRI segmentation of the carotid artery provides vessel wall compositional data (fat fraction and R2*) comparable to time-consuming manual analyses.
May enable efficient carotid wall composition analysis in large cohorts; leaves clinical validation and adoption open.
BACKGROUND: MRI can be used to generate fat fraction (FF) and R2* data, which have been previously shown to characterize the plaque compositional features lipid-rich necrotic core (LRNC) and intraplaque hemorrhage (IPH) in the carotid arteries (CAs). Previously, these data were extracted from CA plaques using time-consuming manual analyses. PURPOSE: To design and demonstrate a method for segmenting the CA and extracting data describing the composition of the vessel wall. STUDY TYPE: Prospective. SUBJECTS: 31 subjects from the Swedish CArdioPulmonary bioImage Study (SCAPIS). FIELD STRENGTH/SEQUENCES: W) quadruple inversion recovery, contrast-enhanced MR angiography (CE-MRA), and 4-point Dixon data were acquired at 3T. ASSESSMENT: w images. Dixon data were used to generate FF and R2* maps. Both manually and automatically generated segmentations of the CA and vessel wall were used to extract compositional data. STATISTICAL TESTS: Two-tailed t-tests were used to examine differences between results generated using manual and automated analyses, and among different configurations of the automated method. Interobserver agreement was assessed with Fleiss' kappa. RESULTS: Automated segmentation of the CA using SVM had a Dice score of 0.89 ± 0.02 and true-positive ratio 0.93 ± 0.03 when compared against ground truth, and median qualitative score of 4/5 when assessed visually by multiple observers. Vessel wall regions of 0.5 and 1 mm yielded compositional information similar to that gained from manual analyses. Using the 0.5 mm vessel wall region, the mean difference was 0.1 ± 2.5% considering FF and 1.1 ± 5.7[1/s] for R2*. LEVEL OF EVIDENCE: 1. TECHNICAL EFFICACY STAGE: 1. J. Magn. Reson. Imaging 2020;52:710-719.
No takes yet. Share an insight, caveat, or question.
Ziegler et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: