Key result
In patients with bundle branch block, proximal His bundle capture during para-Hisian pacing can mimic complete loss of His bundle capture, leading to misinterpretation of the response as extranodal.
When performing para-Hisian pacing in patients with bundle branch block, recording retrograde His potential with a second catheter can prevent misinterpreting proximal His bundle capture as an extranodal response.
Answers are grounded in this paper and cite their sources.
Requires caution interpreting para-Hisian pacing in bundle branch block; leaves open whether second-catheter His recording improves accuracy.
Key Teaching Points•Care should be taken in interpreting the results of para-Hisian pacing maneuvers in patients with preexisting, functional or even transient, mechanically induced bundle branch block. In such cases, proximal His bundle capture with sudden QRS prolongation mimics complete loss of His bundle capture and might lead to misinterpretation of the response as extranodal.•Paced QRS morphology should be assessed to differentiate between complete loss of His bundle capture and loss of distal His bundle capture alone. This might be enough in patients with proximal right bundle branch block; however, in patients with proximal left bundle branch block, QRS morphology might be similar with loss of His bundle capture and with proximal His bundle capture.•A further reduction in pacing output or pushing the pacing catheter slightly deeper into the right ventricle to ensure pure right ventricular myocardial capture may be useful to avoid misinterpretation of proximal His bundle capture as pure right ventricular myocardial capture.•This pitfall may be avoided by recording retrograde His potential with a second catheter to confirm the loss of direct His bundle capture rather than relying on the usual observation of sudden QRS prolongation with the decrease in pacing output. •Care should be taken in interpreting the results of para-Hisian pacing maneuvers in patients with preexisting, functional or even transient, mechanically induced bundle branch block. In such cases, proximal His bundle capture with sudden QRS prolongation mimics complete loss of His bundle capture and might lead to misinterpretation of the response as extranodal.•Paced QRS morphology should be assessed to differentiate between complete loss of His bundle capture and loss of distal His bundle capture alone. This might be enough in patients with proximal right bundle branch block; however, in patients with proximal left bundle branch block, QRS morphology might be similar with loss of His bundle capture and with proximal His bundle capture.•A further reduction in pacing output or pushing the pacing catheter slightly deeper into the right ventricle to ensure pure right ventricular myocardial capture may be useful to avoid misinterpretation of proximal His bundle capture as pure right ventricular myocardial capture.•This pitfall may be avoided by recording retrograde His potential with a second catheter to confirm the loss of direct His bundle capture rather than relying on the usual observation of sudden QRS prolongation with the decrease in pacing output.
No takes yet. Share an insight, caveat, or question.
Jastrzębski et al. (2017) studied Bundle branch block. Para-Hisian pacing maneuvers was evaluated. In patients with bundle branch block, proximal His bundle capture during para-Hisian pacing can mimic complete loss of His bundle capture, leading to misinterpretation of the response as extranodal.
Synapse has enriched 10 related papers. Consider them for comparative context: