Key result
Permanent His bundle pacing over a mean of 70 months did not cause new His-Purkinje conduction abnormalities and was associated with stable left ventricular ejection fraction.
Why the study?
Does permanent His bundle pacing cause His-Purkinje conduction disease or deterioration of left ventricular function during long-term follow-up?
Observational (n=20)
Does permanent His bundle pacing cause His-Purkinje conduction disease or deterioration of left ventricular function during long-term follow-up?
Answers are grounded in this paper and cite their sources.
Long-term permanent His bundle pacing is safe, maintaining stable His-Purkinje conduction and left ventricular systolic function without causing new valve dysfunction.
BACKGROUND: Permanent His bundle pacing (HBP) is a physiological alternative to right ventricular pacing. It is not known whether HBP can cause His-Purkinje conduction (HPC) disease. The aim of our study is to assess His bundle capture and its effect on left ventricular (LV) function in long-term follow-up and to determine HPC at the time of pulse generator change (GC) in patients with chronic HBP. METHODS: HB electrograms were recorded from the pacing lead at implant and GC. HBP QRS duration (QRSd), His-ventricular (HV) intervals, and HB pacing thresholds at GC were compared with implant measurements. HPC was assessed by pacing at cycle lengths of 700 ms, 600 ms, and 500 ms at GC. LV internal diameters, ejection fraction (EF), and valve dysfunction at baseline were compared with echocardiography during follow-up. RESULTS: GC was performed in 20 patients (men 13; age 74 ± 14 years) with HBP at 70 ± 24 months postimplant. HV intervals remained unchanged from initial implant (44 ± 4 ms vs 45 ± 4 ms). During HBP at 700 ms, 600 ms, and 500 ms (n = 17), consistent 1:1 HPC was present. HBP QRSd remained unchanged during follow-up (117 ± 20 ms vs 118 ± 23 ms). HBP threshold at implant and GC was 1.9 ± 1.1 V and 2.5 ± 1.2 V @ 0.5 ms. Despite high pacing burden (77 ± 13%), there was no significant change in LVEF (50 ± 14% at implant) during follow-up (55 ± 6%, P = 0.06). CONCLUSIONS: HBP does not appear to cause new HPC abnormalities and is associated with stable HBP QRSd during long-term follow-up. Despite high pacing burden, HBP did not result in deterioration of left ventricular systolic function or cause new valve dysfunction.
No takes yet. Share an insight, caveat, or question.
Vijayaraman et al. (2017) conducted an observational in Chronic His bundle pacing (n=20). Permanent His bundle pacing vs. Baseline (implant measurements) was evaluated on Left ventricular ejection fraction (LVEF) (p=0.06). Permanent His bundle pacing over a mean of 70 months did not cause new His-Purkinje conduction abnormalities and was associated with stable left ventricular ejection fraction.