Key result
A heart-model-based imaging approach accurately reconstructed 3-D cardiac activation sequences from body surface potential maps in rabbit hearts, with a relative error of 0.291 ± 0.009.
Why the study?
Does a heart-model-based imaging approach accurately estimate 3-D cardiac activation sequences compared to intramural bipolar electrograms in a rabbit heart model?
Does a heart-model-based imaging approach accurately estimate 3-D cardiac activation sequences compared to intramural bipolar electrograms in a rabbit heart model?
Answers are grounded in this paper and cite their sources.
A heart-model-based imaging approach can noninvasively estimate 3-D cardiac activation sequences with low relative error compared to direct intramural recordings in a rabbit model.
In the present study, a heart-model-based imaging approach was applied to the rabbit heart, and 3-D cardiac activation sequences were estimated noninvasively from body surface potential maps during in vivo ventricular pacing from different sites. The estimated activation sequences exhibited earliest sites of cardiac activation and patterns of activation that were consistent with those constructed from 3-D activation sequences obtained from simultaneously recorded bipolar electrogram data (from nearly 160 intramural recording sites). The relative errors between the imaged and measured activation sequences were 0.291/spl plusmn/0.009 for the cases studied. The present study suggests that the heart-model-based imaging approach represents an important alternative for noninvasive imaging of cardiac activation that could be useful for basic cardiovascular research and for the diagnosis and management of cardiac diseases.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2005) studied this question. Heart-model-based imaging approach vs. Simultaneously recorded bipolar electrogram data was evaluated on Relative errors between imaged and measured activation sequences. A heart-model-based imaging approach accurately reconstructed 3-D cardiac activation sequences from body surface potential maps in rabbit hearts, with a relative error of 0.291 ± 0.009.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: