Analysis is given to advantages and drawbacks of methods for measuring laser beam center coordinates and determining a range and amount of linear beam displacements using a quadrant photoreceiver, CCD matrix, and dividing plates. It is shown that the quadrant photoreceiver method and the dividing plate method are most sensitive to displacements of a single-mode laser beam. The minimum detected displacement limited by the shot noise of the laser beam in the photoreceiver for a beam 4 µm in diameter is 3 × 10–14 m/Hz–1/2 with a possibility of detecting linear displacements down to 0.85 µm (dividing plate method). The measurement accuracy for the 100-µm-diameter laser beam is 2.5 × 10–13 m/Hz–1/2 with a possibility of detecting linear displacements down to 13 µm (quadrant photoreceiver method). It is shown that the accuracy of the CCD matrix method is 0.01 µm with a possibility of detecting linear displacements that is limited by the CCD matrix size.
No takes yet. Share an insight, caveat, or question.
Azaryan et al. (2019) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: