Key result
Development of pacemaker dependence in ICD patients was associated with increased mortality compared to non-dependent patients (OR 1.48; 95% CI 1.080-2.042; P=0.015).
Cohort (n=1,058)
No
Odds Ratio: 1.48 (95% CI 1.08–2.042)
p-value: p=0.015
Pacemaker dependence signals higher mortality in ICD patients; hypothesis-generating association requiring prospective validation before clinical implications.
BACKGROUND: The prevalence, predictors, and survival for the development of pacemaker dependence (PD) in patients implanted with an implantable cardioverter defibrillator (ICD) are unknown. METHODS: This was a retrospective analysis of 1,550 consecutive patients with ICD implantation at a single center from 1996 to 2008 with a mean of 4.2 ± 3.4 years. Patients with implant intrinsic heart rates less than 40 beats/min (n = 48) and cardiac resynchronization therapy (n = 444) were excluded leaving 1,058 patients in this study. PD was defined as an intrinsic rhythm <40 beats/min after inhibiting the pacemaker, <50 beats/min with transient symptoms of dizziness relieved by resumption of pacing and right ventricle pacing despite algorithms to promote intrinsic conduction at the 3 monthly follow-up ICD clinic visits. Multivariate regression and Cox proportional hazard models were used for analysis. RESULTS: The mean age was 64 ± 13 years; 79% were male with a primary indication for the ICD in 57%. PD occurred in 142 (13.4%) of patients, with a mean time to PD of 2.6 ± 1.9 years. PD was associated with a 48% increased odds for mortality versus non-PD ICD patients during the mean follow-up time of 4.2 ± 3.4 years (adjusted odds ratio = 1.48 [95% confidence interval 1.080-2.042]; P = 0.015). Older age, a history of atrial fibrillation, amiodarone use, and secondary prevention were the strongest predictors for the development of PD. CONCLUSIONS: In this single-center ICD cohort, the development of PD was not uncommon and was associated with decreased survival.
No takes yet. Share an insight, caveat, or question.
Sood et al. (2013) conducted a cohort in Implantable cardioverter defibrillator (ICD) (n=1,058). Pacemaker dependence vs. Non-pacemaker dependence was evaluated on Mortality (OR 1.48, 95% CI 1.080-2.042, p=0.015). Development of pacemaker dependence in ICD patients was associated with increased mortality compared to non-dependent patients (OR 1.48; 95% CI 1.080-2.042; P=0.015).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: