Answers are grounded in this paper and cite their sources.
Compares image quality and artifacts in blood-suppressed and conventional MRI techniques for Moyamoya vasculopathy, suggesting reduced artifacts with DANTE-SPACE.
BACKGROUND AND PURPOSE: To compare the image quality, wall enhancement characteristics, and presence of artifacts between delay-alternating-with-nutation-for-tailored-excitation blood suppressed prepared (DANTE-SPACE) and conventional sampling-perfection-with-application-optimized-contrasts (SPACE) for post-contrast 3D T1-weighted (T1w) intracranial vessel wall MRI (IVW) in Moyamoya vasculopathy (MMV) patients. METHODS: 31 subjects who underwent both DANTE-SPACE and SPACE postcontrast 3D T1w during the same IVW scanning session were included. Two neuroradiologists blinded to the acquisition types evaluated qualitative imaging features including overall image quality, signal-to-noise (SNR), severity of artifacts, arterial and venous suppression, and lesion assessment using Likert scales on DANTE-SPACE and SPACE images. Quantitative wall SNR and contrast-to-noise ratio (CNR) were determined for affected sides on both sequences. Intensity of post-contrast enhancement was also qualitatively assessed. Quantitative contrast enhancement (CE) metrics were derived from the CE map generated with the multi-contrast, multi-planar framework (MOCHA) software. Comparative analyses used permutation tests matched to the data type. Interobserver agreement was assessed using two-way random-effects intraclass correlation coefficients (ICCs). RESULTS: DANTE-SPACE showed significantly reduced arterial (median 1 [IQR 1-1] versus 2 [1-2], P<.001) and venous flow artifacts (1 [1-1] versus 2 [2-3], P<.001) compared with SPACE. Overall image quality did not differ significantly between sequences (P=0.07), nor did qualitative SNR (P=0.99), artifacts (P=0.09), lesion assessment (P=0.32), quantitative wall SNR (P=0.56), or CNR (P=0.19). DANTE-SPACE showed significantly less enhancement in the segment distal to the steno-occlusion compared to SPACE (no enhancement: 83.3% vs 44.0%, P<.001), while the steno-occlusive segment enhancement was similar (P=0.07). Quantitative CE metrics were comparable between sequences (all P>.05). CONCLUSION: DANTE blood suppression on post-contrast 3D T1w SPACE IVW can significantly reduce arterial and venous flow artifacts and distal slow flow pseudo-enhancement in MMV patients relative to conventional SPACE IVW, without altering lesion enhancement characteristics. DANTE-SPACE incorporated into routine IVW protocols may reduce artifacts that can lead to interpretation errors without altering lesion enhancement assessment.
No takes yet. Share an insight, caveat, or question.
Cheng et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: