Key result
Ascending aortic stenting and bridging PCI stabilize hemodynamics in acute type A dissection before surgery.
Why the study?
Acute type A aortic dissection with a completely thrombosed false lumen causing true lumen collapse and coronary malperfusion is a rare but life-threatening condition.
Does ascending aortic stenting followed by PCI improve hemodynamics as a bridge to surgery in a patient with ATAAD and coronary malperfusion?
Case Report (n=1)
Does ascending aortic stenting followed by PCI improve hemodynamics as a bridge to surgery in a patient with ATAAD and coronary malperfusion?
Answers are grounded in this paper and cite their sources.
Ascending aortic stenting can serve as an effective bridge to definitive surgical repair in selected patients with acute type A aortic dissection complicated by true lumen collapse and coronary malperfusion.
BACKGROUND: Acute type A aortic dissection (ATAAD) with a completely thrombosed false lumen that causes true lumen collapse and coronary malperfusion is a rare but life-threatening condition. CASE SUMMARY: A 58-year-old man presented with epigastric and back pain. Subsequently, the patient developed shock. An ATAAD with a completely thrombosed false lumen and true lumen collapse was identified in the ascending aorta, resulting in severe ostial stenosis of the left main coronary artery. A bare-metal stent was deployed in the ascending aorta to restore the true lumen patency. Percutaneous coronary intervention (PCI) using stent struts improved coronary perfusion and hemodynamics. The patient subsequently underwent definitive-stage surgical repair. DISCUSSION: In selected ATAAD cases, ascending aortic stenting enables bridging PCI and hemodynamic stabilization before surgical repair. TAKE-HOME MESSAGE: Ascending aortic stenting may facilitate preoperative bridging PCI for hemodynamic stabilization in selected patients with ATAAD.
No takes yet. Share an insight, caveat, or question.
Inoue et al. (2026) conducted a case report in Acute type A aortic dissection with completely thrombosed false lumen and true lumen collapse (n=1). Ascending aortic stenting and bridging PCI was evaluated on Hemodynamic stabilization and restoration of true lumen patency. Ascending aortic stenting followed by bridging PCI successfully restored true lumen patency and stabilized hemodynamics prior to surgical repair in a patient with acute type A aortic dissection.
Synapse has enriched 10 related papers. Consider them for comparative context: