Key result
CF-guided PVI linked to ~116% higher bilateral first-pass isolation and lower fluoroscopy time vs non-CF.
Why the study?
Data on the clinical and economic implications of contact force-sensing catheters for pulmonary vein isolation in developing countries remain limited.
Does the use of contact force-sensing catheters improve technical, clinical, and economic outcomes compared to non-CF catheters in patients undergoing pulmonary vein isolation for symptomatic paroxysmal atrial fibrillation?
Observational (n=45)
Does the use of contact force-sensing catheters improve technical, clinical, and economic outcomes compared to non-CF catheters in patients undergoing pulmonary vein isolation for symptomatic paroxysmal atrial fibrillation?
Answers are grounded in this paper and cite their sources.
Contact force-sensing catheters for pulmonary vein isolation in paroxysmal atrial fibrillation improve procedural efficiency and first-pass isolation, with a potential short-term economic benefit despite higher upfront costs.
INTRODUCTION: Contact force (CF)-sensing catheters may improve lesion quality and procedural efficiency during pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (AF), but data on their clinical and economic implications in developing countries remain limited. This pilot study evaluated the technical, clinical, and economic outcomes of CF catheters compared with non-CF catheters in symptomatic paroxysmal AF. METHODS: In this pilot study conducted in Vietnam, 45 patients underwent PVI. Technical outcomes included first-pass isolation (FPI), fluoroscopy time, and lesion-related procedural measures. Clinical outcomes included acute pulmonary vein reconnection and AF recurrence at 3 months. An economic analysis was performed from the payer perspective. RESULTS: CF-guided PVI was associated with lower fluoroscopy time than non-CF ablation (12.19±2.46 vs 14.04±2.93 minutes, p = 0.026) and higher bilateral FPI (81.0% vs 37.5%, p = 0.003). Acute reconnection was uncommon in both groups and numerically lower with CF (97.62% vs 91.67% without reconnection; p = 0.170). No procedural complications occurred in either group. Freedom from AF recurrence at 3 months was higher in the CF group (85.7% vs 58.3%). Total procedural cost was higher with CF catheters (201.08±23.56 vs 191.03±9.71 million VND), with an ICER of 36.7 million VND per additional patient free from AF recurrence at 3 months. CONCLUSION: CF-guided PVI was associated with better technical performance and greater procedural efficiency, despite higher upfront costs. Exploratory economic analysis suggested a possible short-term economic benefit. These findings support consideration of CF investment for AF ablation in Vietnam, pending confirmation in larger studies with longer follow-up.
No takes yet. Share an insight, caveat, or question.
Tran et al. (2026) conducted an observational in symptomatic paroxysmal atrial fibrillation (n=45). Contact force (CF)-sensing catheters vs. non-CF catheters was evaluated on bilateral first-pass isolation (FPI) (p=0.003). Contact force-guided pulmonary vein isolation was associated with higher bilateral first-pass isolation and lower fluoroscopy time compared with non-CF catheters.
Synapse has enriched 10 related papers. Consider them for comparative context: