Key result
Retrograde coronary venous wiring enables CRT lead placement, achieving an absolute ~15-point LVEF increase.
Why the study?
Left ventricular lead delivery failure remains a major limitation of cardiac resynchronization therapy, particularly in patients with complex coronary venous anatomy.
Case Report (n=1)
No
Retrograde coronary venous wiring combined with snare-assisted wire externalization and balloon venoplasty provides a feasible bailout strategy for LV lead placement in CRT patients with severe coronary venous stenosis and failed antegrade access.
Answers are grounded in this paper and cite their sources.
Demonstrates feasibility of retrograde LV lead placement in venous stenosis; leaves open efficacy and safety in larger prospective CRT cohorts.
Left ventricular (LV) lead delivery failure remains a major limitation of cardiac resynchronization therapy (CRT), particularly in patients with complex coronary venous anatomy. We report a 65-year-old woman with non-ischemic cardiomyopathy (LVEF 30%, LBBB, QRS 170 ms) referred for CRT-D after a failed implantation attempt elsewhere. Coronary sinus angiography revealed a small-calibre high lateral vein and a lateral vein with severe post-ostial stenosis. After unsuccessful antegrade wiring, a retrograde strategy was employed: a microcatheter and Fielder XT-A guidewire traversed epicardial collaterals from the posterior to the lateral vein. The Fielder XT-A was then exchanged for a 300-cm RG3 guidewire, which was externalized using a gooseneck snare to create a through-and-through rail. Sequential balloon venoplasty (1.5–2.5 mm) dilated the stenotic segment, enabling successful quadripolar LV lead placement. The D1–M2 vector achieved a capture threshold of 1.2 V at 0.5 ms without phrenic nerve stimulation. At 12-month follow-up, the patient improved to New York Heart Association class I with LVEF 45% and no heart failure admissions. This case demonstrates the sequential application of retrograde coronary venous wiring, wire exchange, snare-assisted externalization, and balloon venoplasty—techniques adapted from interventional cardiology—to overcome severely stenotic coronary venous anatomy when conventional antegrade approaches fail. Advanced coronary intervention techniques may provide a reproducible bailout strategy for achieving optimal LV lead positioning in patients with complex coronary venous anatomy.
No takes yet. Share an insight, caveat, or question.
Tirumalai et al. (2026) conducted a case report in Non-ischemic cardiomyopathy with complex coronary venous anatomy and failed prior CRT implantation (n=1). Retrograde coronary venous wiring, wire exchange, snare-assisted externalization, and sequential balloon venoplasty for CRT-D LV lead placement was evaluated on Successful quadripolar LV lead placement and clinical/echocardiographic response at 12 months. Retrograde coronary venous wiring with snare externalization and venoplasty enabled CRT-D LV lead placement, improving LVEF from 30% to 45% and functional class to I at 12 months.
Synapse has enriched 10 related papers. Consider them for comparative context: