Why the study?
Pre-procedure planning for ventricular arrhythmia ablation can be facilitated by electrocardiographic inverse solutions, and the authors aimed to improve localization accuracy using a novel Bayesian approach.
Does an empirical Bayesian method improve the localization accuracy of the electrocardiographic inverse solution compared to classical Tikhonov methods in patients with scar-related ventricular tachycardia?
Does an empirical Bayesian method improve the localization accuracy of the electrocardiographic inverse solution compared to classical Tikhonov methods in patients with scar-related ventricular tachycardia?
A novel empirical Bayesian method significantly improves the accuracy of localizing the origin of ventricular activation compared to classical Tikhonov methods, potentially aiding pre-procedure planning for ablation.
May enhance VT localization accuracy; leaves open whether gains improve ablation outcomes.
OBJECTIVE: Ablation treatment of ventricular arrhythmias can be facilitated by pre-procedure planning aided by electrocardiographic inverse solution, which can help to localize the origin of arrhythmia. Our aim was to improve localization accuracy of the inverse solution by using a novel Bayesian approach. METHODS: The inverse problem of electrocardiography was solved by reconstructing epicardial potentials from 120 body-surface electrocardiograms and from patient-specific geometry of the heart and torso for four patients suffering from scar-related ventricular tachycardia who underwent epicardial catheter mapping, which included pace-mapping. Simulations using dipole sources in patient-specific geometry were also performed. The proposed method, using dynamic spatio-temporal a priori constraints of the solution, was compared with classical Tikhonov methods based on fixed constraints. RESULTS: The mean localization error of the proposed method for all available pacing sites (n=78) was significantly smaller than that achieved by Tikhonov methods; specifically, the localization accuracy for pacing in the normal tissue (n=17) was [Formula: see text] mm (mean ± SD) versus [Formula: see text] mm reported in the previous study using the same clinical data and Tikhonov regularization. Simulation experiments further supported these clinical findings. CONCLUSION: The promising results of in vivo and in silico experiments presented in this study provide a strong incentive to pursuing further investigation of data-driven Bayesian methods in solving the electrocardiographic inverse problem. SIGNIFICANCE: The proposed approach to localizing origin of ventricular activation sequence may have important applications in pre-procedure assessment of arrhythmias and in guiding their ablation treatment.