Transesophageal and transpharyngeal ultrasound demonstrated reversed diastolic flow in neck vessels and revealed the mechanism of torrential aortic regurgitation caused by an aortic dissection flap.
Case Report (n=1)
Answers are grounded in this paper and cite their sources.
Transesophageal and transpharyngeal ultrasound can effectively demonstrate reversed diastolic flow in neck vessels and the mechanism of severe aortic regurgitation caused by an aortic dissection flap.
In the current study, we describe an adult patient with torrential aortic regurgitation due to an aortic dissection flap interfering with aortic cusp motion, in whom a transesophageal echocardiogram with the probe positioned in the upper esophagus and transpharyngeal ultrasound examination demonstrated prominent reversed flow throughout diastole in the left subclavian, left vertebral, left common carotid, and left internal carotid arteries. Another unique finding was the demonstration of aortic valve leaflets held in the fully opened position in diastole by the dissection flap as it prolapsed into the left ventricular outflow tract, dramatically documenting the mechanism of torrential aortic regurgitation in this patient. (ECHOCARDIOGRAPHY, Volume 21, May 2004)
No takes yet. Share an insight, caveat, or question.
Khanna et al. (2004) conducted a case report in Severe aortic regurgitation (n=1). Transesophageal and transpharyngeal ultrasound was evaluated on Demonstration of reversed diastolic flow and mechanism of aortic regurgitation. Transesophageal and transpharyngeal ultrasound demonstrated reversed diastolic flow in neck vessels and revealed the mechanism of torrential aortic regurgitation caused by an aortic dissection flap.
Synapse has enriched 10 related papers. Consider them for comparative context: