Key result
Wire-guided pericardial puncture achieved a similar success rate and fewer inadvertent right ventricular punctures compared to contrast guidance.
Why the study?
The feasibility and safety of wire-guided pericardial access without contrast remained to be investigated.
Does wire-guided pericardial access without contrast improve safety and maintain feasibility compared to contrast-guided access in patients undergoing epicardial mapping and ablation of ventricular tachycardia?
Cohort (n=73)
No
Does wire-guided pericardial access without contrast improve safety and maintain feasibility compared to contrast-guided access in patients undergoing epicardial mapping and ablation of ventricular tachycardia?
Wire-guided pericardial puncture without contrast is a feasible and potentially safer alternative to contrast-guided access for epicardial mapping and ablation of ventricular tachycardia.
Answers are grounded in this paper and cite their sources.
Should not yet change pericardial access practice; leaves open a potential safety advantage of wire guidance pending randomized data.
OBJECTIVE: To investigate the feasibility and safety of wire-guided pericardial access without contrast. METHODS: From January 2014 to February 2019, patients who received epicardial mapping and ablation of ventricular tachycardia in the Beijing Anzhen Hospital were entered into the current study. They were divided into contrast-guided access group or wire-guided access group according to the pericardial puncture technique used. The baseline variables, procedure parameters, complications were collected and compared. RESULTS: During the study period, a consecutive of 73 patients received epicardial access. The initial 32 patients received contrast-guided puncture with success achieved in 30 patients, the remaining 41 patients underwent wire-guided puncture with success achieved in 40 patients (30/32 and 40/41, P = .581). Fluoroscopy time (4.45 ± 0.52 and 4.38 ± 0.46 minutes, P = .891) and access time (5.14 ± 0.58 and 5.34 ± 0.50 minutes, P = .657) were comparable between the two groups. Inadvertent right ventricular puncture occurred more commonly in the contrast-guided group (5/32 and 1/41, P = .038). Though more pericardial effusions (2/32 and 1/41, P = .575), tamponade (2/32 and 1/41, P = .575), and surgical repair (1/32 and 0/41, P = .432) occurred in the contrast-guided group, they reached no statistical difference. CONCLUSION: Wire-guided pericardial puncture exhibits better safety and similar success rates to contrast-guided technique with a trend towards less complications.
No takes yet. Share an insight, caveat, or question.
Long et al. (2019) conducted a cohort in Ventricular tachycardia (n=73). Wire-guided pericardial access without contrast vs. Contrast-guided pericardial access was evaluated on Success of pericardial access (p=0.581). Wire-guided pericardial puncture achieved a similar success rate and fewer inadvertent right ventricular punctures compared to contrast guidance.
Synapse has enriched 10 related papers. Consider them for comparative context: