Key result
Volume loading in septic shock patients with initial PWP lower than CVP significantly increased blood pressure from 94.4 to 118.9 mm Hg without deteriorating pulmonary oxygenating capacity.
Why the study?
Does volume loading improve hemodynamics without deteriorating pulmonary oxygenating capacity in patients with septic shock?
Cohort (n=20)
Does volume loading improve hemodynamics without deteriorating pulmonary oxygenating capacity in patients with septic shock?
Synchronous monitoring of PWP and CVP in septic shock helps identify patients who will respond favorably to fluid loading without respiratory deterioration.
Answers are grounded in this paper and cite their sources.
Supports PWP-CVP monitoring to identify fluid responders in septic shock; leaves open randomized confirmation of benefit.
The effect of volume loading in 20 patients with clinical and bacteriological evidence of generalized sepsis was studied. The patients were divided into two groups according to their response to volume loading. Group A included 9 patients in whom the initial pulmonary capillary wedge pressure (PWP)was lower than the central venous pressure (CVP). In this group the intravenous administration of 5089+/-409ml/24 hr fluids was accompanied by a significant rise in blood pressure from 94.4+/-9.3mm Hg to 118.9+/-6.3 MM Hg with no significant change in pulse rate or CVP. PWP rose from 5.7 +/- 1.8 to 10.0 +/- 1.4. The rise in cardiac output from 8.0+/-1.3 liter/min to 9.7+/-1.1 liter/min was not statistically significant. Group B included 11 patients in whom the initial PWP was higher than the CVP. In this group, signs of fluid overloading appeared after administration of 3151+/-540ml/24 hr. There was no significant change in blood pressure, pulse rate, CVP, PWP or cardiac output. Urine output was adequate in both groups. This volume load did not affect pulmonary oxygenating capacity (PaO2/F1O2) and effective lung compliance in both groups, but the maintenance of an unchanged oxygenating capacity necessitated an increase in PEEP in some patients. Thus, synchronous monitoring of PWP and CVP in septic shock is helpful in selecting patients (Group A) who will best respond to fluid loading without deterioration of pulmonary oxygenating capacity. PEEP ventilation may be necessary in some patients to maintain the favorable effect of volume loading.
No takes yet. Share an insight, caveat, or question.
Krausz et al. (1977) conducted a cohort in Septic shock (n=20). Volume loading vs. Patients with initial PWP higher than CVP was evaluated on Hemodynamic response (blood pressure, PWP, cardiac output). Volume loading in septic shock patients with initial PWP lower than CVP significantly increased blood pressure from 94.4 to 118.9 mm Hg without deteriorating pulmonary oxygenating capacity.
Synapse has enriched 10 related papers. Consider them for comparative context: