Key result
Contactless heart rate estimation using a Microsoft Kinect v2 device achieved a 2% error rate compared to gold-standard Holter measurements when incorporating prior lifestyle knowledge.
Why the study?
Does contactless heart rate estimation using Microsoft Kinect v2 accurately measure heart rate compared to a Holter monitor?
Cross-Sectional (n=20)
No
Does contactless heart rate estimation using Microsoft Kinect v2 accurately measure heart rate compared to a Holter monitor?
Contactless heart rate detection using Microsoft Kinect v2 provides accurate heart rate estimation with low error rates compared to a Holter monitor.
Answers are grounded in this paper and cite their sources.
Supports contactless HR monitoring feasibility; leaves open prospective validation in diverse clinical settings.
Contactless detection is one of the new frontiers of technological innovation in the field of healthcare, enabling unobtrusive measurements of biomedical parameters. Compared to conventional methods for Heart Rate (HR) detection that employ expensive and/or uncomfortable devices, such as the Electrocardiograph (ECG) or pulse oximeter, contactless HR detection offers fast and continuous monitoring of heart activities and provides support for clinical analysis without the need for the user to wear a device. This paper presents a validation study for a contactless HR estimation method exploiting RGB (Red, Green, Blue) data from a Microsoft Kinect v2 device. This method, based on Eulerian Video Magnification (EVM), Photoplethysmography (PPG) and Videoplethysmography (VPG), can achieve performance comparable to classical approaches exploiting wearable systems, under specific test conditions. The output given by a Holter, which represents the gold-standard device used in the test for ECG extraction, is considered as the ground-truth, while a comparison with a commercial smartwatch is also included. The validation process is conducted with two modalities that differ for the availability of a priori knowledge about the subjects' normal HR. The two test modalities provide different results. In particular, the HR estimation differs from the ground-truth by 2% when the knowledge about the subject's lifestyle and his/her HR is considered and by 3.4% if no information about the person is taken into account.
No takes yet. Share an insight, caveat, or question.
Gambi et al. (2017) conducted a cross-sectional in Healthy (Heart rate monitoring validation) (n=20). Contactless heart rate detection using Microsoft Kinect v2 vs. Holter monitor (gold-standard) was evaluated on Heart rate estimation error compared to ground truth. Contactless heart rate estimation using a Microsoft Kinect v2 device achieved a 2% error rate compared to gold-standard Holter measurements when incorporating prior lifestyle knowledge.
Synapse has enriched 10 related papers. Consider them for comparative context: