Key result
Ultrasound and DXA measured intra-abdominal adipose tissue with minimal bias compared to CT/MRI, but wide limits of agreement caution against their clinical use except for DXA volume.
Why the study?
Agreement between intra-abdominal adipose tissue quantified by alternative methods and reference standards CT and MRI was not established.
Do alternative methods (ultrasound, bioelectrical impedance analysis, DXA) accurately quantify intra-abdominal adipose tissue compared to reference standards (CT or MRI)?
Meta-Analysis
Do alternative methods (ultrasound, bioelectrical impedance analysis, DXA) accurately quantify intra-abdominal adipose tissue compared to reference standards (CT or MRI)?
Answers are grounded in this paper and cite their sources.
Ultrasound and DXA measure intra-abdominal adipose tissue with minimal bias compared to CT or MRI, but wide limits of agreement limit their clinical utility, whereas bioelectrical impedance analysis systematically underestimates it.
Objective This meta‐analysis aimed to assess the agreement between intra‐abdominal adipose tissue (IAAT) quantified by alternative methods and the reference standards, computed tomography (CT) and magnetic resonance imaging (MRI). Methods MEDLINE and EMBASE electronic databases were systematically searched to identify studies that quantified IAAT thickness, area, or volume by a comparator method and CT or MRI. Using an inverse variance weighted approach (random‐effects model), the mean differences and 95% limits of agreement (LoA) were pooled between methods. Results The meta‐analysis included 24 studies using four comparator methods. The pooled mean differences were −0.3 cm (95% LoA: −3.4 to 3.2 cm; P = 0.400) for ultrasound and −11.6 cm 2 (95% LoA: −43.1 to 19.9 cm 2 ; P = 0.004) for bioelectrical impedance analysis. Dual‐energy x‐ray absorptiometry (DXA) quantified both IAAT area and volume with mean differences of 8.1 cm 2 (95% LoA: −98.9 to 115.1 cm 2 ; P = 0.061) and 10 cm 3 (95% LoA: −280 to 300 cm 3 ; P = 0.808), respectively. Conclusions Ultrasound and DXA measure IAAT with minimal bias from CT or MRI, while bioelectrical impedance analysis systematically underestimates IAAT. However, with the exception of DXA for IAAT volume, the wide LoA caution against clinical or research use of the comparator methods and emphasize the need to optimize alternatives to the reference standards.
No takes yet. Share an insight, caveat, or question.
Murphy et al. (2019) conducted a meta-analysis in Intra-abdominal adipose tissue quantification. Alternative methods (ultrasound, bioelectrical impedance analysis, DXA) vs. Reference standards (CT and MRI) was evaluated on Mean difference in IAAT quantification between ultrasound and reference standards (MD -0.3 cm, 95% CI -3.4 to 3.2, p=0.400). Ultrasound and DXA measured intra-abdominal adipose tissue with minimal bias compared to CT/MRI, but wide limits of agreement caution against their clinical use except for DXA volume.