Key result
Touch-up RF after balloon ablation shows no increase in periprocedural complications vs. balloon alone.
Why the study?
Balloon ablation for PVI is well established for AF, but generalizable evidence on the status and outcomes of touch-up ablation is limited.
Does touch-up radiofrequency ablation following balloon ablation for pulmonary vein isolation maintain acute success and procedural safety compared to balloon-only or radiofrequency-only ablation in patients with atrial fibrillation?
Cohort (n=51,402)
Yes
Does touch-up radiofrequency ablation following balloon ablation for pulmonary vein isolation maintain acute success and procedural safety compared to balloon-only or radiofrequency-only ablation in patients with atrial fibrillation?
Touch-up applications using radiofrequency ablation after balloon ablation yield high acute success rates without significantly increasing non-phrenic nerve complications compared to standard approaches.
Answers are grounded in this paper and cite their sources.
Touch-up applications after balloon PVI were not linked to excess non-PNP complications; leaves open whether selective use improves long-term outcomes in observational data.
Background Balloon ablation for pulmonary vein isolation (PVI) is a well-established treatment option for atrial fibrillation. Although some patients require touch-up ablation, generalizable evidence is limited. Objective This study aimed to investigate the current status and outcomes of touch-up applications using a nationwide registry in Japan. Methods Patients ≥18 years of age who underwent first-time PVI between January 2017 and December 2020 were included using the data from the Japanese Catheter Ablation registry. The annual trends in the proportion of cases requiring touch-up ablation with radiofrequency ablation were determined, and the associations of ablation strategies with acute success and periprocedural complications were analyzed using logistic regression analysis. Results Of the 51,402 patients included, 28,412 and 22,990 patients underwent PVI using radiofrequency ablation and balloon ablation, respectively. In the balloon ablation group, 1462 (6.4%) patients required touch-up applications, and the proportion of cases requiring touch-up applications decreased during the study period from 9.5% in 2017 to 5.5% in 2020 (P for trend < .001). The proportion of acute success was >99% across all ablation strategies. Although 2.5% of the patients in the touch-up ablation group had phrenic nerve palsy, the composite of complications, except for phrenic nerve palsy, was not significantly increased in the balloon + touch-up ablation group compared with that in the balloon ablation–only group and radiofrequency ablation group. Conclusion Touch-up applications following balloon ablation are required in some cases. Touch-up ablation with radiofrequency ablation may be a treatment option when achieving successful PVI using balloon ablation is difficult.
No takes yet. Share an insight, caveat, or question.
Kanaoka et al. (2025) conducted a cohort in Atrial fibrillation (n=51,402). Radiofrequency touch-up ablation following balloon ablation vs. Balloon ablation only was evaluated on Composite of periprocedural complications except for phrenic nerve palsy (OR 1.10, 95% CI 0.73-1.64, p=0.66). Touch-up radiofrequency applications after balloon ablation did not increase the composite risk of periprocedural complications (excluding phrenic nerve palsy) compared to balloon ablation alone.