Key result
Mitral valve repair using a V-clamp device resulted in no procedural complications and improved respiratory signs and quality of life in four dogs at 6-month follow-up.
Why the study?
Mitral valve disease is common in dogs, and the study aimed to describe cases of dogs undergoing mitral valve repair with a V-clamp device and evaluate follow-up cardiac function.
Does mitral valve repair via a V-clamp device improve symptoms and cardiac function in dogs with mitral valve regurgitation?
Case Report (n=4)
Does mitral valve repair via a V-clamp device improve symptoms and cardiac function in dogs with mitral valve regurgitation?
Answers are grounded in this paper and cite their sources.
Transcatheter edge-to-edge repair using a V-clamp device is a feasible and safe treatment option for mitral valve regurgitation in dogs, leading to improved clinical signs.
Mitral valve disease is a common heart disease in dogs. The aim of this study was to describe the cases of dogs that underwent mitral valve repair via a V-clamp device and to provide long-term follow-up data on cardiac function after mitral valve repair. Four dogs with mitral valve regurgitation who experienced coughing, and dyspnea underwent surgical mitral valve repair between December 2023 and March 2024. The patients were evaluated via transthoracic and transesophageal echocardiography. Echocardiography revealed mitral valve leaflet regurgitation. Mitral valve repair was performed under general anesthesia using a V-clamp device introduced through an introducer wire guide. Echocardiography was conducted at baseline and during the 6-month follow-up. Blood analysis results after surgical repair were normal. Follow-up echocardiography revealed no complications related to the procedure, with all dogs demonstrating improved respiratory signs and quality of life after repair. No adverse reactions were reported after surgery. A V-clamp device was used to repair mitral valve regurgitation in four dogs. Mitral valve repair via a V-clamp device is another treatment option for mitral valve disease in dogs.
No takes yet. Share an insight, caveat, or question.
Petchdee et al. (2024) conducted a case report in Mitral valve regurgitation (n=4). Mitral valve repair via a V-clamp device was evaluated on Complications, respiratory signs, and quality of life. Mitral valve repair using a V-clamp device resulted in no procedural complications and improved respiratory signs and quality of life in four dogs at 6-month follow-up.
Synapse has enriched 10 related papers. Consider them for comparative context: