Standardized MRI ‐Based Quantification of Epicardial Adipose Tissue Volume: Reproducibility and Agreement With Cardiac Computed Tomography

View Full Paper
JGJudith GronwaldSGSvante GerschZBZoé Böttiger

Key Result

Standardized MRI-based epicardial adipose tissue volume quantification showed excellent reproducibility but only moderate agreement with CT (ρ = 0.627), with systematically higher values on MRI.

Key Points

  • To assess the reproducibility of a standardized MRI technique for measuring epicardial adipose tissue volume and its correlation with cardiac computed tomography.
  • Retrospective study of 127 patients with aortic stenosis and 11 volunteers.
  • MRI measurements obtained through manual volumetry on cine sequences; CT with voxel-thresholding approach.
  • Statistical evaluations included Spearman correlation, Bland-Altman analysis, and intraclass correlation coefficients for reproducibility.
  • Moderate correlation between MRI and CT EATV measures (ρ = 0.627).
  • Excellent intra-observer ICC for CT (0.983) and MRI (0.955), and inter-observer ICCs for CT (0.994) and MRI (0.970).
  • MRI-derived EATV quantification displayed high scan-rescan reliability (ICC: 0.985).

Study Design

Type

Observational (n=138)

Structured PICO

Does standardized MRI-based quantification of epicardial adipose tissue volume agree with cardiac CT in patients with aortic stenosis?

P
Population
127 patients with aortic stenosis (AS) (78 ± 6 years; 38% female) and 11 volunteers (74 ± 7 years, 45% female)
I
Intervention
Standardized MRI-based method for epicardial adipose tissue volume (EATV) quantification using manual volumetry on end-diastolic short-axis cine stacks
C
Comparator
Cardiac computed tomography (CT) EATV quantification by manual delineation and voxel-thresholding
O
Outcome
Inter-modality agreement between MRI and CT, and reproducibility (inter-observer, intra-observer, and scan-rescan)surrogate

Standardized MRI-based quantification of epicardial adipose tissue volume is highly reproducible but yields systematically higher values than CT, limiting direct comparability between the two modalities.

Main Result

Effect estimate: ρ = 0.627

Limitations

  • Systematically higher values on MRI limit direct comparability with CT.

Abstract

BACKGROUND: Epicardial adipose tissue volume (EATV) is increasingly recognized as a cardiometabolic risk marker associated with adverse outcomes. The most established approach for EATV quantification is cardiac computed tomography (CT). MRI offers a radiation-free alternative allowing simultaneous assessment of myocardial function and tissue characteristics; however, standardization and validation are limited. PURPOSE: To evaluate a standardized MRI-based method for EATV quantification and determine its agreement with CT. STUDY TYPE: Retrospective. POPULATION: 127 patients with aortic stenosis (AS) (78 ± 6 years; 38% female) who underwent paired CT and MRI and 11 volunteers (74 ± 7 years, 45% female) who underwent repeat MRI after ≥ 6 weeks. FIELD STRENGTH/SEQUENCE: Short-axis balanced steady-state free precession cine sequence at 3T (AS patients) and 1.5T (volunteers). ASSESSMENT: On CT, EATV was quantified by manual delineation of the visceral pericardium and voxel-thresholding (-190 to -30 HU). MRI-based EATV quantification used manual volumetry with delineation of the visceral pericardium and epicardium on end-diastolic short-axis cine stacks. STATISTICAL TESTS: Inter-modality agreement was assessed by Spearman correlation and Bland-Altman analysis. Reproducibility was evaluated in 20 patients using intraclass correlation coefficient (ICC) and coefficient of variation (CoV). Scan-rescan reproducibility for MRI-derived EATV quantification was assessed using ICC and linear regression. p < 0.05 was considered significant. RESULTS: ), with a significant moderate correlation (ρ = 0.627) between measures. Inter- and intra-observer analyses showed excellent reproducibility for both modalities (CT: intra-observer ICC: 0.983, inter-observer ICC: 0.994; MRI: intra-observer ICC: 0.955, inter-observer ICC: 0.970). MRI-derived EATV quantification also showed excellent scan-rescan reproducibility (ICC: 0.985). DATA CONCLUSION: The standardized MRI-based approach enabled highly reproducible EATV measurements with excellent repeatability. Agreement with CT was moderate, with systematically higher values on MRI, limiting direct comparability. EVIDENCE LEVEL: 3. STAGE OF TECHNICAL EFFICACY: 2.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Gronwald et al. (2026) conducted an observational in Aortic stenosis (n=138). MRI-based epicardial adipose tissue volume (EATV) quantification vs. Cardiac computed tomography (CT) was evaluated on Inter-modality agreement between MRI and CT (ρ = 0.627). Standardized MRI-based epicardial adipose tissue volume quantification showed excellent reproducibility but only moderate agreement with CT (ρ = 0.627), with systematically higher values on MRI.