Key result
Higher baseline left ventricular end-diastolic pressure independently predicted adverse in-hospital outcomes during balloon aortic valvuloplasty (OR 1.08 per mm Hg increase; 95% CI 1.02-1.14).
Why the study?
Does higher baseline LVEDP predict adverse in-hospital outcomes in patients with severe symptomatic aortic stenosis undergoing balloon aortic valvuloplasty?
Cohort (n=111)
No
Does higher baseline LVEDP predict adverse in-hospital outcomes in patients with severe symptomatic aortic stenosis undergoing balloon aortic valvuloplasty?
Odds Ratio: 1.08 (95% CI 1.02–1.14)
p-value: p=0.02
Elevated baseline left ventricular end-diastolic pressure is an independent predictor of adverse in-hospital outcomes, including death and MI, during balloon aortic valvuloplasty.
OBJECTIVES: In this study, we examined the predictive value of the left ventricular end-diastolic pressure (LVEDP) in patients undergoing balloon aortic valvuloplasty (BAV). BACKGROUND: The LVEDP is a useful indicator of hemodynamic status in patients with severe aortic stenosis. In BAV, decompensated heart failure is associated with worse outcomes. METHODS: We identified all consecutive patients with severe symptomatic aortic stenosis who underwent retrograde BAV at the Massachusetts General Hospital from 2004 to 2008. Patients were stratified and compared according to their baseline LVEDP into ≤15 mm Hg, 16-20 mm Hg, 21-25 mm Hg, and ≥26 mm Hg. Procedural and in-hospital outcomes and adverse events were compared. Multivariate logistic regression was used for the adjusted analysis. RESULTS: A total of 111 patients with a mean age of 83±11 years underwent BAV. Of these, the LVEDP was ≤15 mm Hg in 29 (26%), 16-20 mm Hg in 41 (37%), 21-25 mm Hg in 16 (14%), and ≥26 mm Hg in 25 (23%) patients. Baseline characteristics were similar among the four groups. Noticeably, patients with high LVEDP levels had significantly higher rates of the combined endpoint of in-hospital death, myocardial infarction (MI), cardiopulmonary arrest, and tamponade was P = 0.02. Periprocedural MI was more common among those with higher LVEDP (16% vs. 2.3%; P = 0.04). Multivariate analysis revealed LVEDP (OR 1.08, for each mm Hg increase in pressure, 95 % CI 1.02-1.14), small LV chamber size, and New York Heart Association class as independent predictors of adverse outcomes. CONCLUSIONS: The LVEDP is an important independent predictor of poor in-hospital outcome during BAV. In these patients, the immediate hemodynamic status may be more important than the baseline left ventricular systolic function. Hemodynamic optimization before or during BAV should be considered and may be beneficial.
No takes yet. Share an insight, caveat, or question.
Cubeddu et al. (2012) conducted a cohort in Severe symptomatic aortic stenosis (n=111). Left ventricular end-diastolic pressure (LVEDP) vs. Lower LVEDP levels was evaluated on Adverse outcomes (combined endpoint of in-hospital death, myocardial infarction, cardiopulmonary arrest, and tamponade) (OR 1.08, 95% CI 1.02-1.14, p=0.02). Higher baseline left ventricular end-diastolic pressure independently predicted adverse in-hospital outcomes during balloon aortic valvuloplasty (OR 1.08 per mm Hg increase; 95% CI 1.02-1.14).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: