Key result
PFA achieves first-pass PVI in ~63% of patients, with greater impedance drops in left-sided veins.
Why the study?
Does per-application local impedance change and tissue proximity indication associate with first-pass PVI and gap occurrence in adults undergoing PFA-PVI?
Observational (n=8)
No
Does per-application local impedance change and tissue proximity indication associate with first-pass PVI and gap occurrence in adults undergoing PFA-PVI?
Local impedance changes during pulsed-field ablation are higher in left-sided pulmonary veins and correlate with acute conduction gaps, suggesting its potential utility for real-time lesion assessment.
Hypothesis-generating for impedance-guided PVI; larger prospective studies needed before clinical consideration.
Background Local impedance (LI) at the electrode–tissue interface is a promising surrogate of contact quality and lesion effectiveness during pulsed-field ablation (PFA). However, real-world relationships among per-application LI change (ΔLI), a system-derived tissue proximity indication (TPI), and acute pulmonary vein isolation (PVI) outcomes remain insufficiently characterized. Purpose To evaluate whether per-application ΔLI and TPI are associated with (i) first-pass PVI and (ii) gap occurrence, and to compare ΔLI between left- and right-sided pulmonary veins (LPVs vs RPVs). Methods We conducted a single-center observational analysis in adults undergoing PFA-PVI with a variable-loop circular, multielectrode catheter integrated with an electroanatomical mapping system. Electrode-level LI was extracted from procedural video recordings and device logs. Baseline LI was the pre-delivery stable mean immediately before each application. Post-delivery LI was the instantaneous nadir (peak deflection) after energy delivery, without smoothing. For each train within an application (three trains per application), per-train ΔLI was calculated as baseline minus the instantaneous nadir for that train. For each active electrode, the electrode-level ΔLI (per application) was obtained by summing the three per-train ΔLI values. The per-application total ΔLI was then computed as the sum of electrode-level ΔLI across all active electrodes. TPI positivity was determined by the system’s impedance-based proximity criterion at the application level. Endpoints were patient-level first-pass PVI and PV-level presence of a conduction gap. In an exploratory analysis, applications were also categorized by per-application total ΔLI > 40 Ω, and for each pulmonary vein (PV) the count of such applications was compared between PVs with and without a conduction gap. Results Eight patients were analyzed. First-pass PVI was achieved in 5/8 (62.5%); conduction gaps occurred in 3/8 (37.5%), all in the right pulmonary veins. The mean number of applications per procedure was 21± 4. A total of 1,578 active-electrode impedance pairs were analyzed. The mean per-application total ΔLI was 21 ± 20 Ω overall; it was 28 ± 22 Ω in LPVs and 16 ± 17 Ω in RPVs, with a significantly greater ΔLI on the left side (p<0.05). Applications with TPI positivity showed a numerically larger ΔLI than TPI-negative applications, without reaching statistical significance. Among PVs with a conduction gap, the mean count of applications per vein with per-application total ΔLI > 40 Ω was significantly lower than in PVs without a gap (non-gap vs gap: 19.2 ± 3.1 vs 14.0 ± 1.0 per vein, p<0.05). Conclusion Per-application total ΔLI was higher in left- than right-sided pulmonary veins, and all acute gaps occurred on the right. Veins with a gap had fewer applications achieving total ΔLI > 40 Ω, while TPI positivity tracked with larger ΔLI without statistical significance.
No takes yet. Share an insight, caveat, or question.
Kimura et al. (2026) conducted an observational in Patients undergoing pulmonary vein isolation (n=8). Pulsed-field ablation (PFA) was evaluated on Patient-level first-pass PVI and PV-level presence of a conduction gap. Pulsed-field ablation achieved first-pass pulmonary vein isolation in 62.5% of patients, with significantly greater local impedance drops in left-sided versus right-sided veins (28 vs 16 Ω, p<0.05).