Key result
Magnetic resonance imaging of right atrial casts correlated strongly with true volumes, providing a reliable means to study right atrial volumes and phasic function.
Why the study?
Does cardiac-gated cine MR imaging accurately measure right atrial volumes and phasic function in cadaveric casts and healthy subjects?
Observational (n=22)
Does cardiac-gated cine MR imaging accurately measure right atrial volumes and phasic function in cadaveric casts and healthy subjects?
Cardiac-gated cine MR imaging is a reliable method for assessing right atrial volumes and phasic function, demonstrating that right atrial volumes are generally larger than left atrial volumes.
Answers are grounded in this paper and cite their sources.
Validates cardiac MRI for right atrial volume research in healthy subjects; leaves open clinical adoption pending outcome data.
PURPOSE: To assess magnetic resonance (MR) imaging of the right atrium by measuring volumes of right atrial casts and determining right atrial volume cycles in healthy subjects. MATERIALS AND METHODS: Fourteen human cadaveric atrial casts were imaged and right atrial volumes of eight subjects were measured with cardiac-gated cine MR. Volumes were calculated and right and left atrial volumes were compared. RESULTS: Measured volumes of right atrial casts correlated well (r = .99, P < .001) with true volumes with a small underestimation noted (-7.2 mL +/- 2.3 [standard deviation], P < .001). The maximum in vivo right atrial volume averaged 77 mL/m2 +/- 11 of body area. The right atrial reservoir and conduit functions accounted for, on average, 58% and 19%, respectively, of the ventricular stroke volume; the remaining 23% came from atrial contraction. Right-to-left peak volume ratio averaged 1.41 +/- 0.15 (P < .001), and all volume measurements except conduit volumes were statistically significantly larger in the right atrium than the left. CONCLUSIONS: MR imaging provides a reliable means to study right atrial volumes and phasic function.
No takes yet. Share an insight, caveat, or question.
Järvinen et al. (1994) conducted an observational in Healthy (n=22). Magnetic resonance (MR) imaging vs. True volumes (for casts) and left atrial volumes (for subjects) was evaluated on Correlation of measured volumes of right atrial casts with true volumes (r = 0.99, p=< .001). Magnetic resonance imaging of right atrial casts correlated strongly with true volumes, providing a reliable means to study right atrial volumes and phasic function.
Synapse has enriched 10 related papers. Consider them for comparative context: