Key result
Cold stored donor platelets yield ~94% clinical consensus across platforms for light transmission aggregometry.
Why the study?
Current external quality assessment for light transmission aggregometry audits only trace interpretation, prompting investigation into whether donor platelets could assess analytical and post-analytical performance.
Answers are grounded in this paper and cite their sources.
Cold stored donor platelets can serve as stable and reliable external quality assessment material for light transmission aggregometry across different laboratory platforms.
BACKGROUND: To achieve accreditation for ISO 15189, laboratories are required to either participate in EQA exercises or intra-laboratory comparisons to meet the standard. Light transmission aggregometry performed by laboratory scientists for the clinical investigation of possible platelet function defects is time dependent. Current EQA available audits the interpretation of platelet aggregation traces. OBJECTIVES: Could NEQAS BC provide external quality assessment (EQA) material to centres employing Light Transmission Aggregometry LTA for clinical investigation of platelet function? The use of fresh donor platelets could audit more of the analytical and post analytical aspects of light transmission aggregation than currently available. METHODS: A pool of donor platelets was split into aliquots that were distributed to testing centres across England, Scotland and Wales for testing within a 72 h window. Participating centres employed their locally validated testing methods for LTA assays, for agonists including ADP; Arachidonic acid; Collagen; Epinephrine; Ristocetin; TRAP and U46619. RESULTS: Five different aggregation platforms were used including: Chronolog 700; Helena Aggram; PAP-8; Stago TA-8V and Sysmex CN-series. Sample packs were tested through the 72 h window with most sites performing LTA on the EQA material on day one of the three. CONCLUSION: The % consensus of interpretations provided by participants for agonists including: ADP; Arachidonic acid; Collagen; Epinephrine and Ristocetin ranged from 94% to 100% indicating that the material is stable plus centres using different aggregometers returned the same clinical interpretations.
No takes yet. Share an insight, caveat, or question.
Reilly‐Stitt et al. (2025) studied Platelet function testing. Cold stored donor platelets was evaluated on Consensus of interpretations provided by participants for agonists. Cold stored donor platelets used as external quality assessment material for light transmission aggregometry yielded a 94% to 100% consensus of clinical interpretations across different platforms.
Synapse has enriched 10 related papers. Consider them for comparative context: