Key result
Transvenous laser lead extraction in octogenarians achieved a complete procedural success rate of 92.9% and a clinical success rate of 98.6%, with no procedure-related mortality.
Why the study?
An increasing number of octogenarians with cardiac implantable electronic devices require lead extractions, but this population is often considered high risk for surgical procedures.
Is transvenous lead extraction using powered extraction sheaths safe and effective in octogenarians?
Cohort (n=71)
Yes
Is transvenous lead extraction using powered extraction sheaths safe and effective in octogenarians?
Transvenous lead extraction using powered sheaths is safe and highly effective in octogenarians, indicating that advanced age alone should not be a contraindication for the procedure.
Supports TLE in experienced centers for octogenarians; leaves open need for prospective validation before broader adoption.
BACKGROUND: In the aging population equipped with cardiac implantable electronic devices, an increasing number of octogenarians require lead extractions. This patient population is often considered as a high-risk group for surgical procedures. We, therefore, investigated the safety and efficacy of transvenous lead extraction in octogenarians using powered extraction sheaths. METHODS: Between January 2013 and March 2017, 403 patients underwent lead extraction at two high-volume lead extraction centers. A total of 71 octogenarians were treated with laser lead extraction and were included in this analysis. Primary extraction method was laser lead extraction, with additional use of mechanical rotational sheaths or femoral snares, if necessary. Patient-based and procedural data were collected and analyzed retrospectively. RESULTS: Mean age was 83.5 ± 3.3 years, 64.7% were males. A total of 152 leads were extracted. The mean lead dwell time of treated leads was 10.2 ± 5.2 years. Complete procedural success rate was 92.9%, while clinical success was achieved in 98.6%. Failure of extraction occurred in one patient (1.4%). In six (7.7%) patients, additional mechanical rotational sheaths or femoral snares were used. Overall complication rate was 4.2%, including one (1.4%) major (RA perforation) and two (2.8%) minor complications. No procedure-related mortality was observed in any of the patients. CONCLUSION: Transvenous lead extraction in octogenarians with old leads is safe and effective when performed in experienced centers. Patient's age should therefore not be considered as contraindication for lead extraction using powered extraction sheaths.
No takes yet. Share an insight, caveat, or question.
Bürger et al. (2021) conducted a cohort in Cardiac implantable electronic device requiring lead extraction (n=71). Transvenous laser lead extraction was evaluated on Complete procedural success. Transvenous laser lead extraction in octogenarians achieved a complete procedural success rate of 92.9% and a clinical success rate of 98.6%, with no procedure-related mortality.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: