Key result
Ineffective CRT pacing ≥1% is linked to ~90% lower odds of CRT response.
Why the study?
Little was known about the relationship between the percentage of ineffective CRT pacing and CRT response.
Does a high percentage of ineffective CRT pacing (%i-CRT ≥ 1%) reduce the prevalence of CRT responders in CRT recipients?
Cohort (n=44)
Does a high percentage of ineffective CRT pacing (%i-CRT ≥ 1%) reduce the prevalence of CRT responders in CRT recipients?
Answers are grounded in this paper and cite their sources.
A high percentage of ineffective CRT pacing (≥1%) is strongly associated with an unfavorable CRT response, highlighting potential hidden causes like latency, AF, and PVCs that can be targeted therapeutically.
INTRODUCTION: An effective cardiac resynchronization therapy (CRT) algorithm classifies each left ventricular (LV) pace as effective or ineffective based on electrogram morphology. Loss of capture, latency, pseudo-fusion during sinus rhythm, and rapid ventricular responses due to atrial fibrillation (AF) and premature ventricular conductions (PVCs) are potential causes of ineffective CRT pacing. However, little is known about the relationship between percentage of ineffective CRT pacing (%i-CRT) and CRT response. METHODS AND RESULTS: Among 136 consecutive CRT recipients, we evaluated 44 patients with an effective CRT algorithm. The primary outcome was the prevalence of CRT responders, defined as a reduction in the LV end-systolic volume by ≥ 10% 6 months after implantation. The median values of percent ventricular pacing and %i-CRT were 97.5% (interquartile range [IQR]: 96.4%-98.3%) and 0.3% (IQR: 0.1%-1.0%), respectively. Patients in the highest quartile of %i-CRT (%i-CRT ≥ 1%) showed a significantly lower prevalence of CRT responders (4 [36.4%] vs. 28 [84.8%], p = 0.004) than the remaining quartiles. The univariate analysis showed that %i-CRT ≥ 1% was negatively associated with the CRT response (odds ratio: 0.10, 95% confidence interval: 0.02-0.48). The most frequent cause of ineffective pacing was rapid ventricular responses due to AF and/or PVCs, whereas the cause of the highest %i-CRT in this cohort was latency. A total of three nonresponders with a high %i-CRT showed favorable responses after therapeutic interventions for their hidden causes. CONCLUSION: High %i-CRT could be associated with an unfavorable CRT response and provide insights into hidden causes and therapeutic targets.
No takes yet. Share an insight, caveat, or question.
Oka et al. (2025) conducted a cohort in Cardiac resynchronization therapy (CRT) recipients (n=44). High percentage of ineffective CRT pacing (%i-CRT ≥ 1%) vs. Lower percentage of ineffective CRT pacing (%i-CRT < 1%) was evaluated on Prevalence of CRT responders (reduction in LV end-systolic volume by ≥ 10% at 6 months) (OR 0.10, 95% CI 0.02-0.48, p=0.004). A high percentage of ineffective cardiac resynchronization therapy pacing (≥1%) was associated with a significantly lower prevalence of CRT responders (36.4% vs 84.8%; OR 0.10, 95% CI 0.02-0.48).
Synapse has enriched 10 related papers. Consider them for comparative context: