Key result
Parametrized diastolic filling-based E-wave analysis differentiated pseudonormal from normal filling patterns with a sensitivity of 0.90 and specificity of 0.86 without requiring knowledge of E'.
Why the study?
Does parametrized diastolic filling-based E-wave analysis distinguish pseudonormal from normal filling patterns in subjects with normal left ventricular ejection fraction?
Observational (n=42)
Blinded analysis
Does parametrized diastolic filling-based E-wave analysis distinguish pseudonormal from normal filling patterns in subjects with normal left ventricular ejection fraction?
Fractionating E-wave deceleration time into stiffness and relaxation components can accurately differentiate normal from pseudonormal diastolic filling patterns without requiring E' measurements.
BACKGROUND: Pseudonormal Doppler E-wave filling patterns indicate diastolic dysfunction but are indistinguishable from the normal filling pattern. For accurate classification, maneuvers to alter load or to additionally measure peak E' are required. E-wave deceleration time (DT) has been fractionated into its stiffness (DTs) and relaxation (DTr) components (DT=DTs+DTr) by analyzing E-waves via the parametrized diastolic filling formalism. The method has been validated with DTs and DTr correlating with simultaneous catheterization-derived stiffness (dP/dV) and relaxation (τ) with r=0.82 and r=0.94, respectively. We hypothesize that DT fractionation can (1) distinguish between unblinded (E' known) normal versus pseudonormal age-matched groups with normal left ventricular ejection fraction, and (2) distinguish between blinded (E' unknown) normal versus pseudonormal groups, based solely on E-wave analysis. METHODS AND RESULTS: Data (763 E-waves) from 15 age-matched, pseudonormal (elevated E/E') and 15 normal subjects were analyzed. Conventional echocardiographic and parametrized diastolic filling stiffness (k) and relaxation (c) parameters and DTs and DTr were compared. Conventional diastolic function parameters did not differentiate between unblinded groups, whereas k, c (P<0.001) and DTs, DTr (P<0.001) did. Independent, blinded (E' not provided) analysis of 42 subjects (30 subjects from unblinded training set and 12 additional subjects from validation set, 581 E-waves) showed that R (=DTr/DT) had high sensitivity (0.90) and specificity (0.86) in differentiating pseudonormal from normal once E' revealed actual classification. CONCLUSIONS: arametrized diastolic filling-based E-wave analysis (k, c or DTs and DTr) can differentiate normal versus pseudonormal filling patterns without requiring knowledge of E'.
No takes yet. Share an insight, caveat, or question.
Mossahebi et al. (2015) conducted an observational in Diastolic dysfunction (n=42). Parametrized diastolic filling-based E-wave analysis (DT fractionation) vs. Conventional echocardiographic parameters was evaluated on Differentiation of pseudonormal from normal filling patterns (Sensitivity 0.90, Specificity 0.86, p=<0.001). Parametrized diastolic filling-based E-wave analysis differentiated pseudonormal from normal filling patterns with a sensitivity of 0.90 and specificity of 0.86 without requiring knowledge of E'.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: