Key result
Echocardiographic assessment of mobile echoes on prosthetic valves showed moderate inter-observer agreement for identification and no agreement for labelling.
Why the study?
What is the inter-observer variability in identifying mobile echoes on prosthetic heart valves using transoesophageal echocardiography?
Cross-Sectional
Yes
What is the inter-observer variability in identifying mobile echoes on prosthetic heart valves using transoesophageal echocardiography?
Significant inter-observer variability exists in identifying and labeling mobile echoes on prosthetic heart valves, necessitating standardized echocardiographic criteria.
Answers are grounded in this paper and cite their sources.
TEE identification of prosthetic valve strands shows poor reproducibility; leaves open their clinical significance pending standardized criteria.
AIMS: To test the hypothesis that inter-observer variability accounts for the wide variation in reported prevalences of fibrin strands on prosthetic heart valves and to develop criteria for their identification and reporting. METHODS AND RESULTS: A videotape with 30 sequences of prosthetic heart valves imaged by transoesophageal echocardiography and showing abnormalities such as strands, microbubbles, and spontaneous echocardiographic contrast, was assessed in 13 European and three American centres. There were three duplicated examples, unbeknown to the observers. Definitions and reported prevalence rates of the abnormalities were analysed, and inter- and intra-observer agreement estimated with the kappa statistic. Mobile echoes were identified in 40 to 80% of the sequences on the tape. The reported prevalence of mobile echoes correlated with the time spent reporting the tape. There was moderate inter-observer agreement for the identification of any mobile echoes (kappa = 0.38), but no agreement for their labelling (kappa = 0.22), in spite of similar definitions. Intra-observer reproducibility was good (agreement in 76% of the reduplicated sequences). CONCLUSIONS: The true prevalence and potential significance of mobile echoes on prosthetic heart valves cannot be assessed unless inter-observer consensus on echocardiographic criteria for identifying such echoes is reached.
No takes yet. Share an insight, caveat, or question.
Adrian Ionescu (1999) conducted a cross-sectional in Prosthetic heart valves. Transoesophageal echocardiography assessment was evaluated on Inter-observer agreement for the identification of any mobile echoes (kappa = 0.38). Echocardiographic assessment of mobile echoes on prosthetic valves showed moderate inter-observer agreement for identification and no agreement for labelling.