Key result
Dynamic tracking 4D Flow MRI correlates with indirect MRI but yields 16 mL higher TR volumes.
Why the study?
To address limitations in tricuspid regurgitation quantification by MRI or TTE using a new 4D Flow MRI method with retrospective tricuspid valve annular tracking.
Does 4D Flow MRI with dynamic annular tracking improve the quantification and reproducibility of tricuspid regurgitation volume compared to conventional MRI and TTE methods in patients with TR?
Cross-Sectional (n=30)
Does 4D Flow MRI with dynamic annular tracking improve the quantification and reproducibility of tricuspid regurgitation volume compared to conventional MRI and TTE methods in patients with TR?
Mean Difference: 16 (95% CI -19–51)
p-value: p=<0.0001
4D Flow MRI with dynamic tricuspid valve tracking provides highly reproducible quantification of tricuspid regurgitation volume, potentially offering greater sensitivity than conventional MRI techniques.
Dynamic 4D Flow MRI may increase detected TR severity; leaves open standardization and outcome validation before clinical use.
Purpose To address limitations in tricuspid regurgitation (TR) quantification by magnetic resonance imaging (MRI) or transthoracic echocardiography (TTE), a new method is proposed to directly quantify TR volume (TR V ) using 4D Flow MRI with retrospective tricuspid valve (TV) annular tracking. Methods Thirty patients with TR were prospectively enrolled. TR V was quantified using four MRI‐based methods: (i) indirect, (ii) direct (2D phase‐contrast), (iii) 4D Flow with a static TV plane, and (iv) 4D Flow with dynamic annular tracking. Reproducibility and agreement were assessed in terms of TR grading against standard MRI‐ and TTE‐based methods. Results The dynamic 4D Flow method correlated strongly with all other MRI methods ( r = 0.77–0.81, p < 0.0001) but consistently yielded higher TR V values. Compared with the indirect method, it showed a Bland–Altman bias of 16 mL (limits of agreement: −19 to 51 mL), along with the highest agreement (intraclass correlation coefficient of 0.88). Agreement in TR severity grading was poor across methods (kappa ≤ 0.07), with dynamic 4D Flow classifying more cases as moderate or severe. Agreement with TTE was slight (kappa = 0.17, p = 0.27) with concordant TR grading in 50% of patients. Inter‐observer reproducibility was excellent ( r = 0.99, bias = 0.7 mL, kappa = 0.80). Conclusion 4D Flow with dynamic TV tracking offers a reproducible and potentially more sensitive method for TR V quantification than conventional MRI techniques. Despite limited alignment with TTE, this technique may help overcome key imaging limitations and improve TR clinical evaluation, especially in complex cases.
No takes yet. Share an insight, caveat, or question.
Riva et al. (2026) conducted a cross-sectional in tricuspid regurgitation (n=30). 4D Flow MRI with dynamic annular tracking vs. conventional MRI techniques and TTE was evaluated on TR volume (TR V) quantification (bias 16 mL, 95% CI -19 to 51, p=<0.0001). 4D Flow MRI with dynamic tricuspid valve tracking correlated strongly with other MRI methods (r=0.77-0.81, p<0.0001) but yielded higher TR volumes, with a bias of 16 mL compared to indirect MRI.