Key result
Small annuli show similar bioprosthetic valve failure rates to large annuli after supra-annular TAVR.
Why the study?
Data on mid- to long-term durability of supra-annular self-expanding valves after TAVR across annular sizes, especially in Asian cohorts with smaller annuli, remain limited.
Does small annular size increase the risk of structural valve deterioration or bioprosthetic valve failure in patients undergoing TAVR with supra-annular self-expanding valves?
Cohort (n=370)
No
Does small annular size increase the risk of structural valve deterioration or bioprosthetic valve failure in patients undergoing TAVR with supra-annular self-expanding valves?
Answers are grounded in this paper and cite their sources.
Supra-annular self-expanding valves provide favorable mid-term durability in Asian patients, mitigating the adverse hemodynamic profile traditionally associated with small aortic annuli.
ranscatheter aortic valve replacement (TAVR) in patients with small aortic annuli (SAA) has been associated with higher residual transvalvular gradients, increasing the risk of prosthesis-patient mismatch (PPM), structural valve deterioration (SVD), and adverse outcomes.In the randomized SMART Trial, supra-annular selfexpanding valves (SEVs) have demonstrated hemodynamic advantages over balloon-expandable valves in patients with SAA. 1 However, data on midto long-term durability across annular sizesespecially in an Asian cohort where smaller annuli are more prevalent 2 -remain limited.This study evaluated mid-term clinical outcomes, bioprosthetic valve dysfunction, SVD, and bioprosthetic valve failure (BVF) in an Asian cohort undergoing TAVR with SEVs, stratified by annular size.From May 2010 to December 2023, consecutive patients with symptomatic severe aortic stenosis undergoing TAVR with CoreValve/Evolut platforms in Taiwan were enrolled.Patients were stratified by computed tomography-derived annular diameter into SAA (#23 mm) and large aortic annulus (LAA; >23 mm).Clinical follow-up included scheduled visits and echocardiography at 1 month, 6 months, 1 year, and annually thereafter.Valve-related outcomes were defined according to Valve Academic Research Consortium-3 criteria.3 SVD and BVF were assessed using standardized definitions, and only patients with at least 2 postprocedural echocardiograms were included.A competing risk analysis was conducted using the Fine-Gray method to estimate the probability of SVD in the event of death that would impede the development of SVD.Predictors of SVD were identified using a multivariable analysis, with significance set at P < 0.05.Among 370 patients (excluding valve-in-valve and redo-TAVR), 191 (51.6%) had SAA and 179 (48.4%) had LAA.Mean age was 81 years, 57% were female, and the median Society of Thoracic Surgeons score was 6.4% (IQR: 3.6-9.7).Bicuspid valves were present in 12.2%.Patients with SAA were more often female, had smaller body surface area, and had fewer comorbidities.Procedural characteristics were comparable, with predominantly transfemoral access under conscious sedation.At 30 days, mean pressure gradients (MPGs) (7.6 ± 3.9 vs 8.0 ± 3.9 mm Hg), indexed effective orifice area (1.11 ± 0.25 vs 1.09 ± 0.24 cm 2 ), and rates of moderate/severe PPM (16.2% vs 18.0%) were comparable between SAA and LAA groups.An elevated postprocedural MPG $20 mm Hg was rare (1.1%) and did not differ between groups.Over a median follow-up of 3.5 years (IQR: 1.8-5.9years; maximum: 13 years), 168 patients (45.4%) died, with 57 (33.9%) from cardiovascular causes.Kaplan-Meier estimates of all-cause mortality at 1, 3, 5, and 7 years were 10.9% (95% CI: 7.6-14.0),26.5%
No takes yet. Share an insight, caveat, or question.
Chen et al. (2026) conducted a cohort in Symptomatic severe aortic stenosis (n=370). Small aortic annulus (≤23 mm) vs. Large aortic annulus (>23 mm) was evaluated on Bioprosthetic valve failure (BVF) incidence per 100 patient-years (p=0.549). In patients undergoing TAVR with supra-annular self-expanding valves, bioprosthetic valve failure incidence was comparable between small and large annuli.
Synapse has enriched 10 related papers. Consider them for comparative context: