Key result
Elevated LVEDP in cardiac allografts is linked to ~75% lower calcium channel beta-subunit mRNA.
Why the study?
LV diastolic dysfunction is a major cause of cardiac allograft failure, and the role of L-type calcium channel subunit gene expression in allografts developing diastolic heart failure needed investigation.
Observational (n=72)
Reduced beta-subunit mRNA may contribute to allograft diastolic dysfunction; hypothesis-generating finding leaves open causal and therapeutic roles.
BACKGROUND: Left ventricular diastolic dysfunction is a major cause of cardiac allograft failure. Multimeric L-type calcium channels (alpha1-, alpha2/delta-, and beta-subunits) are essential for excitation/contraction coupling in the heart. Their gene expression was studied in allografts that developed diastolic heart failure. METHODS AND RESULTS: mRNA levels of calcium channel subunits were measured by competitive reverse transcriptase-polymerase chain reaction in microbiopsy samples from the interventricular septum. Size and tissue variabilities between biopsy samples were assessed by determination of cardiac calsequestrin mRNA levels. In the cardiac allografts studied, mRNA levels in microbiopsy samples were considered to represent left ventricular gene expression, because septal and left ventricular gene expression in Northern blots was equivalent, and left ventricles contracted homogeneously. Biopsy samples (n=72) were taken from allografts with normal left ventricular end-diastolic pressure (LVEDP; 8 to 13 mm Hg; n=30), moderately elevated LVEDP (14 to 18 mm Hg; n=26), and elevated LVEDP (19 to 28 mm Hg; n=16). Increased LVEDP was related to slowed diastolic relaxation determined by the time constant tau (r2=0.86), whereas systolic performance (dP/dt; ejection fraction) was preserved. With increasing LVEDP, mRNA levels of the pore-forming alpha1c-subunit (n=15) and of the regulatory alpha2/delta-subunit (n=17) remained unchanged but decreased exponentially (r2=-0.83) for the regulatory beta-subunit (n=40). Compared with cardiac allografts with normal LVEDP (n=15), beta-subunit mRNA level was reduced by 75% at elevated LVEDP (n=9; P=0.012). In an explanted, diastolically failing cardiac allograft, beta-subunit expression was reduced correspondingly by 72% and 76% on the mRNA level in septal and left ventricular myocardium and by 80% on the protein level. CONCLUSIONS: The downregulated expression of the calcium channel beta-subunit might contribute to altered calcium handling in diastolically failing cardiac allografts.
No takes yet. Share an insight, caveat, or question.
Hullin et al. (1999) conducted an observational in Diastolic heart failure of the cardiac allograft (n=72). Elevated left ventricular end-diastolic pressure vs. Normal left ventricular end-diastolic pressure was evaluated on Calcium channel beta-subunit mRNA level (75% reduction, p=0.012). Elevated left ventricular end-diastolic pressure in cardiac allografts was associated with a 75% reduction in calcium channel beta-subunit mRNA levels compared to normal pressure (P=0.012).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: