Key result
High frequency electrocardiography detected myocardial ischemia, with 7 of 10 dog experiments showing reduced amplitude zones during coronary occlusion that resolved upon reperfusion.
Why the study?
Does high frequency electrocardiography detect myocardial ischemia during coronary artery occlusion in a canine model?
Does high frequency electrocardiography detect myocardial ischemia during coronary artery occlusion in a canine model?
Answers are grounded in this paper and cite their sources.
High frequency electrocardiography with signal averaging can detect morphological changes in the QRS complex indicative of myocardial ischemia in a canine model.
The ability to detect cardiac ischemia in dogs was studied using high frequency electrocardiography and signal averaging technique. Ischemia was induced via a balloon occluding cuff placed around the left anterior descending coronary artery. Three surface orthogonal bipolar leads (X, Y, and Z) were recorded prior to inflation of the occluding cuff. The cuff was then inflated, causing a complete occlusion of the coronary artery. The surface electrocardiogram was recorded before and during ligation and during reperfusion. The recorded waveforms were divided into sequential 10-15 second segments representing different stages of the ischemic state and were aligned using cross-correlation scheme, averaged and band pass filtered between 150-250 Hz. Analysis of the filtered high frequency QRS complexes revealed that coronary ligation was accompanied by changes in waveform morphology including the appearance of zones of reduced amplitude. In seven out of ten experiments reduced amplitude zones were absent before the ligation, present during the occlusion and absent following reperfusion. In two experiments, reduced amplitude zones that were present prior to ligation became wider during occlusion. In one experiment no reduced amplitude zone was present during any stage of the experiment. Such zones may represent slow conduction in regions of the heart rendered ischemia during coronary ligation. Therefore, the morphology of the high frequency QRS complex, as determined by analysis of the signal averaged electrocardiogram, may provide useful information regarding the presence of myocardial ischemia.
No takes yet. Share an insight, caveat, or question.
Abboud et al. (1989) studied Cardiac ischemia (n=10). Coronary artery occlusion vs. Prior to occlusion and following reperfusion was evaluated on Changes in waveform morphology including the appearance of zones of reduced amplitude in high frequency QRS complexes. High frequency electrocardiography detected myocardial ischemia, with 7 of 10 dog experiments showing reduced amplitude zones during coronary occlusion that resolved upon reperfusion.