Key result
ccTGA linked to ~560% higher risk of pacemaker implantation before total cavopulmonary connection.
Why the study?
Brady-arrhythmia requiring pacemaker implantation remains a Fontan-specific complication before and after total cavopulmonary connection.
Does pacemaker implantation for brady-arrhythmia affect survival or complications in patients undergoing total cavopulmonary connection?
Cohort (n=620)
Does pacemaker implantation for brady-arrhythmia affect survival or complications in patients undergoing total cavopulmonary connection?
Odds Ratio: 6.6 (95% CI 2–21.5)
p-value: p=0.002
Pacemaker implantation in patients with Fontan circulation is associated with stable lead thresholds and does not adversely affect survival or increase the risk of Fontan-specific complications.
ccTGA warrants pre-TCPC rhythm vigilance; leaves open whether targeted monitoring alters Fontan outcomes.
BACKGROUND: Brady-arrhythmia requiring pacemaker implantation remains one of the Fontan-specific complications before and after total cavopulmonary connection. METHODS: A retrospective analysis of 620 patients who underwent total cavopulmonary connection between 1994 and 2021 was performed to evaluate the incidence of brady-arrhythmia and the outcomes after pacemaker implantation. Factors associated with the onset of brady-arrhythmia were identified. RESULTS: A total of 52 patients presented with brady-arrhythmia and required pacemaker implantation. Diagnosis included 16 sinus node dysfunctions, 29 atrioventricular blocks, and 7 junctional escape rhythms. Pacemaker implantation was performed before total cavopulmonary connection (n = 16), concomitant with total cavopulmonary connection (n = 8), or after total cavopulmonary connection (n = 28, median 1.8 years post-operatively). Freedom from pacemaker implantation following total cavopulmonary connection at 10 years was 92%. Twelve patients needed revision of electrodes due to lead dysfunction (n = 9), infections (n = 2), or dislocation (n = 1). Lead energy thresholds were stable, and freedom from pacemaker lead revision at 10 years after total cavopulmonary connection was 78%. Congenitally corrected transposition of the great arteries (odds ratio: 6.6, confidence interval: 2.0-21.5, p = 0.002) was identified as a factor associated with pacemaker implantation before total cavopulmonary connection. Pacemaker rhythms for Fontan circulation were not a risk factor for survival (p = 0.226), protein-losing enteropathy/plastic bronchitis (p = 0.973), or thromboembolic complications (p = 0.424). CONCLUSIONS: In our cohort of patients following total cavopulmonary connection, freedom from pacemaker implantation at 10 years was 92% and stable atrial and ventricular lead energy thresholds were observed. Congenitally corrected transposition of the great arteries was at increased risk for pacemaker implantation before total cavopulmonary connection. Having a pacemaker in the Fontan circulation had no adverse effect on survival, protein-losing enteropathy/plastic bronchitis, or thromboembolic complications.
No takes yet. Share an insight, caveat, or question.
Bohn et al. (2023) conducted a cohort in Total cavopulmonary connection (Fontan palliation) (n=620). Congenitally corrected transposition of the great arteries vs. Other cardiac anatomies was evaluated on Pacemaker implantation before total cavopulmonary connection (OR 6.6, 95% CI 2.0-21.5, p=0.002). Congenitally corrected transposition of the great arteries was associated with an increased risk of pacemaker implantation before total cavopulmonary connection (OR 6.6; 95% CI 2.0-21.5; p=0.002).