Key result
Multidetector computed tomography detected thrombotic deposits in 100% of analyzed membrane oxygenators after ECMO weaning, with a mean clot volume of 51.7 cm.
Why the study?
Can multidetector computed tomography (MDCT) be used to directly visualize and quantify thrombotic deposits within extracorporeal membrane oxygenators?
Observational (n=20)
Can multidetector computed tomography (MDCT) be used to directly visualize and quantify thrombotic deposits within extracorporeal membrane oxygenators?
MDCT imaging reveals that clot formation within ECMO membrane oxygenators is a ubiquitous finding despite adequate systemic anticoagulation.
Answers are grounded in this paper and cite their sources.
MDCT enables direct quantification of oxygenator thrombosis in ECMO; leaves open whether it improves exchange timing or outcomes.
Oxygenator thrombosis is a serious complication in extracorporeal membrane oxygenation (ECMO) and may necessitate a system exchange. Coagulation and fibrinolysis parameters, flow dynamics, and gas transfer performance are currently used to evaluate the degree of oxygenator thrombosis, but there is no technical approach for direct visualization and quantification of thrombotic deposits within the membrane oxygenator (MO). We used multidetector computed tomography (MDCT) with three-dimensional postprocessing to assess the incidence of oxygenator thrombosis, to quantify thrombus extent, and to localize clot distribution. Twenty heparin-coated MOs after successful weaning were analyzed. Mean ECMO support time was 7 ± 4 days, mean activated partial thromboplastin time (aPTT) during ECMO was 59 ± 20 seconds. Thrombotic deposits were detected in all MOs. The mean clot volume was 51.7 ± 22.3 cm. All thrombotic deposits were located in the venous, i.e., inlet part of the device, without apparent evidence of embolization in patients. There was no correlation between clot volume and ECMO support time or aPTT. Clot formation within the MO is a common finding in ECMO despite adequate systemic anticoagulation. The clinical significance of thrombus formation and its influence on gas exchange capacity and hemostatic complications have to be addressed in further studies.
No takes yet. Share an insight, caveat, or question.
Dornia et al. (2014) conducted an observational in Oxygenator thrombosis in extracorporeal membrane oxygenation (n=20). Multidetector computed tomography (MDCT) was evaluated on Incidence of oxygenator thrombosis. Multidetector computed tomography detected thrombotic deposits in 100% of analyzed membrane oxygenators after ECMO weaning, with a mean clot volume of 51.7 cm.
Synapse has enriched 10 related papers. Consider them for comparative context: