Key result
Pentaspline PFA linked to greater hemolysis and eGFR decline vs balloon-in-basket catheters.
Why the study?
Pulsed field ablation for pulmonary vein isolation in AF can cause hemolysis and renal effects, which may be modulated by catheter design.
Does pulsed field ablation with a pentaspline catheter induce more hemolysis and renal dysfunction compared to a balloon-in-basket catheter in patients with atrial fibrillation?
Observational (n=81)
No
Does pulsed field ablation with a pentaspline catheter induce more hemolysis and renal dysfunction compared to a balloon-in-basket catheter in patients with atrial fibrillation?
Pulsed field ablation utilizing a pentaspline catheter leads to greater periprocedural hemolysis and acute renal function decline compared to a balloon-in-basket catheter, likely driven by differences in catheter design and energy exposure to the blood pool.
Answers are grounded in this paper and cite their sources.
Pentaspline PFA was associated with greater hemolysis and renal decline than balloon-in-basket; leaves open whether catheter design reduces systemic effects.
BACKGROUND: Pulsed field ablation (PFA) is a non-thermal modality for pulmonary vein isolation (PVI) in atrial fibrillation (AF). While effective, hemolysis and renal effects may occur, potentially modulated by catheter design. METHODS: In this prospective, non-randomized, single-center study, patients underwent PFA-based PVI using either a balloon-in-basket catheter or a pentaspline catheter. Hemolysis (LDH, bilirubin, haptoglobin, myoglobin) and renal markers (creatinine, eGFR) were assessed immediately before and the morning after ablation. RESULTS: Eighty-one patients were included (balloon-in-basket: n=35; pentaspline: n=46), with comparable baseline characteristics. Both groups achieved acute 100% first-pass PVI. The pentaspline group received more PFA applications (32 [32-40] vs. 16 [16-18], p<0.001). Hemolytic markers increased significantly in both groups but were more pronounced in the pentaspline group: LDH Δ+99 [76-121] vs. +59 [43-69] U/L, bilirubin Δ+5.2 [2.4-8.5] vs. +2.4 [0.2-5.1] µmol/L, haptoglobin Δ-28 [-39 to -18] vs. -6 [-17 to +5] mg/dL (all p<0.001). Myoglobin increased modestly in both groups: Δ+12.0 [0-26.0] vs. +11.0 [0-21.5] ng/mL (p=0.696). Only the pentaspline group exhibited a significant renal function decline: creatinine Δ+6.0 [2.2-11.5] vs. +2.0 [-4.0-4.4] µmol/L (p=0.009); eGFR Δ-4.5 [-10.8 to -1.3] vs. -1.0 [-3.5-5.0] mL/min (p=0.002). CONCLUSION: The pentaspline catheter induced more hemolysis and a measurable decline in renal function. Myoglobin increases were similar in both groups and unlikely to explain the renal findings. Catheter design and energy delivery appear to shape the systemic impact profile of PFA.
No takes yet. Share an insight, caveat, or question.
Wenzel et al. (2025) conducted an observational in Symptomatic atrial fibrillation (n=81). Pentaspline PFA catheter vs. Balloon-in-basket PFA catheter was evaluated on Change in estimated glomerular filtration rate (eGFR) at 24 hours (p=0.002). The pentaspline PFA catheter induced greater hemolysis and a measurable decline in renal function compared to the balloon-in-basket system in patients undergoing pulmonary vein isolation.