Key result
Echocardiographic peak strain values generated by EchoPAC and VVI showed only moderate correlation and differed in most left ventricular segments.
Why the study?
Does the choice of speckle tracking software (EchoPAC vs VVI) affect the measurement of left ventricular peak strain and time to peak strain in healthy subjects?
Cross-Sectional (n=47)
Does the choice of speckle tracking software (EchoPAC vs VVI) affect the measurement of left ventricular peak strain and time to peak strain in healthy subjects?
Answers are grounded in this paper and cite their sources.
Peak strain values are highly software-dependent and not directly comparable between EchoPAC and VVI, highlighting the need for caution in clinical application.
BACKGROUND: Echocardiographic speckle tracking strain has gained clinical importance. However, the comparability of measurements between different software systems is not well defined. METHODS: In 47 healthy subjects left ventricular (LV) two-dimensional (2D) peak strain and time to peak strain (TTP) generated by EchoPAC (2DS) and velocity vector imaging (VVI) were compared. For each type of strain (longitudinal [LS], circumferential [CS], and radial strain [RS]) we compared global, anatomical level and segmental values. RESULTS: When comparing 2DS to VVI, Pearson correlation coefficients (r) of global LS, CS, and RS were 0.68, 0.44, and 0.59, respectively (all P < 0.05). Correlation of global TTP was higher: 0.81(LS), 0.80 (CS), and 0.68 (RS), all P < 0.01. Segmental peak strain differed significantly between 2DS and VVI in 8/18 (LS), 17/18 (CS), and 15/18 (RS) LV segments (P < 0.05). However, segmental TTP significantly differed only in 5/18 (LS), 7/18 (CS), and 4/18 (RS) of LV segments. Similar strain gradients were found for both systems: apical strain was higher than basal and midventricular strain in LS and CS, with a reversed pattern for RS (P < 0.05). CONCLUSION: TTP strain as well as strain gradients were comparable between VVI and 2DS, but most peak strain values were not. The software-dependency of peak strain values must be considered in clinical application. Further studies comparing the diagnostic and prognostic accuracy of strain values generated by different software systems are mandatory.
No takes yet. Share an insight, caveat, or question.
Biaggi et al. (2011) conducted a cross-sectional in Healthy (n=47). EchoPAC (2DS) vs. Velocity vector imaging (VVI) was evaluated on Pearson correlation coefficient of global longitudinal strain between 2DS and VVI (r 0.68, p=< 0.05). Echocardiographic peak strain values generated by EchoPAC and VVI showed only moderate correlation and differed in most left ventricular segments.
Synapse has enriched 10 related papers. Consider them for comparative context: