Key result
Off-label percutaneous pulmonary valve implantation was successfully performed in 23 patients, proving safe and feasible with uneventful RVOT preparation and valve implantations.
Why the study?
Is percutaneous pulmonary valve implantation safe and feasible for off-label indications such as conduit-free RVOT or undersized conduits?
Observational (n=23)
Is percutaneous pulmonary valve implantation safe and feasible for off-label indications such as conduit-free RVOT or undersized conduits?
Percutaneous pulmonary valve implantation appears safe and feasible for off-label indications such as conduit-free RVOT or undersized conduits when adequate landing zones are created by prestenting.
Answers are grounded in this paper and cite their sources.
Off-label PPVI may be feasible in select native RVOT cases; hypothesis-generating and should not yet change practice.
INTRODUCTION: Percutaneous pulmonary valve implantation is now considered feasible and safe. "Native" right ventricular outflow tract (RVOT), small diameter conduits (<16 mm) and relatively large RVOT with a dynamic outflow aneurysm are currently considered off-label uses. Extending indications creates concerns of safety, ethics, reimbursement, and liability. AIM OF STUDY: To report the safety and feasibility of off-label application of percutaneous pulmonary valve implantation. DESIGN: Retrospective analysis of prospectively collected data. PATIENTS AND METHODS: Off-label indications: conduit-free RVOT or patients with an existing but undersized conduit. RESULTS: Twenty-one Melody® valves and two Sapien® valves were successfully implanted in 23 patients (16.9 years; range 6.1-80.5 years). In 22 patients, prestenting was performed 4.8 months (range 0-69.2) before valve implantation (15 covered and 13 bare stents). Stent endothelial ingrowth was allowed for at least 2 months prior to implantation of the percutaneous valve if stent stability or sealing by the covering was presumed to be insufficient. Group 1 patients (n = 8) had a "conduit-free" RVOT after transannular/infundibular patch and after prestenting underwent percutaneous pulmonary valve implantation (PPVI), with a final RVOT diameter of 21.5 mm (range 16-26 mm). Group 2 patients consisted of two elderly patients with pulmonary valve stenosis and severe RVOT calcifications. Group 3 (n = 13) had an existing conduit (nominal 15.9 ± 3.2 mm; range 10-20 mm). The conduit was augmented from 14.7 ± 3.5 to 20 ± 1.6 mm with PPVI. The RVOT preparation and valve implantations were uneventful. CONCLUSIONS: PPVI is safe and feasible in selected patients with an off-label indication. Creating an adequate "landing zone" by prestenting makes the procedure safe and predictable. Updating the indications for PPVI should be considered.
No takes yet. Share an insight, caveat, or question.
Boshoff et al. (2012) conducted an observational in Off-label indications for percutaneous pulmonary valve implantation (n=23). Percutaneous pulmonary valve implantation was evaluated on Safety and feasibility. Off-label percutaneous pulmonary valve implantation was successfully performed in 23 patients, proving safe and feasible with uneventful RVOT preparation and valve implantations.