Key result
Surgical mitral valve replacement with Epic bioprosthesis yields ~77% five-year overall survival.
Why the study?
Real-world mid-term clinical experiences and outcomes after surgical mitral valve replacement with the Epic bioprosthesis in a high-volume Japanese heart center remained to be reported.
Does surgical mitral valve replacement with the Epic bioprosthesis prevent all-cause mortality and mitral valve reintervention in patients requiring mitral valve replacement?
Observational (n=122)
No
Does surgical mitral valve replacement with the Epic bioprosthesis prevent all-cause mortality and mitral valve reintervention in patients requiring mitral valve replacement?
Surgical mitral valve replacement with the Epic bioprosthesis demonstrates satisfactory mid-term survival, stable hemodynamics, and a very low rate of structural valve deterioration over 5 years.
Mid-term Epic mitral bioprosthesis data support acceptable performance in selected patients; leaves open durability and comparative effectiveness questions.
OBJECTIVE: This study aimed to report "real-world" mid-term clinical experiences and outcomes after surgical mitral valve replacement with the Epic bioprosthesis in a high-volume Japanese heart center. METHODS: Patients undergoing surgical mitral valve replacement with the Epic bioprosthesis from 2012 to 2023 were enrolled. Postoperative outcomes, survival, and hemodynamic performance were analyzed. The study endpoints were all-cause mortality, freedom from mitral valve reintervention, and major adverse cardiac events. RESULTS: A total of 122 patients (mean age: 73 ± 8 years, 73 males) successfully underwent surgical mitral valve replacement with the Epic bioprosthesis (25 mm, n = 22; 27 mm, n = 37; 29 mm, n = 26; and 31 mm, n = 37). The primary valve etiologies were infective endocarditis (n = 17), stenosis (n = 18), stenosis and regurgitation (n = 13), regurgitation (n = 73), and thrombosis (n = 1). The median follow-up period was 33 (interquartile range: 20-48) months. Overall survival rates at 1, 3, and 5 years after mitral valve replacement were 86.8%, 82.0%, and 76.9%. The rates of freedom from rehospitalization for heart failure were 96.7% at 1 year, 95.5% at 3 years, and 91.2% at 5 years. The mean pressure gradient was 5 (interquartile range: 4-6.4) mmHg at discharge, 5.4 (interquartile range: 4.3-6.9) mmHg at 1 year, and 5.4 (interquartile range: 4-7.5) mmHg at late follow-up (Friedman test, p = 0.46). During the study period, only one patient required reintervention because of valve deterioration at 31 postoperative months. CONCLUSION: The clinical outcomes of mitral valve replacement with the Epic bioprosthesis are satisfactory, with stable hemodynamics and extremely low incidence of structural valve deterioration and reintervention over 5 years.
No takes yet. Share an insight, caveat, or question.
Gyoten et al. (2025) conducted an observational in Mitral valve disease (n=122). Abbott Epic mitral bioprosthesis was evaluated on 5-year overall survival (95% CI 65.3-85.0). Surgical mitral valve replacement with the Epic bioprosthesis demonstrated satisfactory mid-term outcomes, with a 5-year overall survival rate of 76.9% and a 91.0% rate of freedom from major adverse cardiac events.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: