Key result
A super-concentrated 62-electrode configuration for inverse potential mapping without an a priori model achieved a high correlation with the epicardial source model and a mean in vivo localization error of 5.3 mm.
Why the study?
Can detailed anterior epicardial potential information be derived using only 62 torso electrodes without an a priori model?
Can detailed anterior epicardial potential information be derived using only 62 torso electrodes without an a priori model?
Answers are grounded in this paper and cite their sources.
Detailed anterior epicardial potential information can be accurately derived using a super-concentrated 62-electrode torso configuration without an a priori biophysical model.
INTRODUCTION: In inverse potential mapping, local epicardial potentials are computed from recorded body surface potentials (BSP). When BSP are recorded with only a limited number of electrodes, in general biophysical a priori models are applied to facilitate the inverse computation. This study investigated the possibility of deriving epicardial potential information using only 62 torso electrodes in the absence of an a priori model. METHODS: Computer simulations were used to determine the optimal in vivo positioning of 62 torso electrodes. Subsequently, three different electrode configurations, i.e., surrounding the thorax, concentrated precordial (30 mm inter-electrode distance) and super-concentrated precordial (20 mm inter-electrode distance) were used to record BSP from three healthy volunteers. Magnetic resonance imaging (MRI) was performed to register the electrode positions with respect to the anatomy of the patient. Epicardial potentials were inversely computed from the recorded BSP. In order to determine the reconstruction quality, the super-concentrated electrode configuration was applied in four patients with an implanted MRI-conditional pacemaker system. The distance between the position of the ventricular lead tip on MRI and the inversely reconstructed pacing site was determined. RESULTS: The epicardial potential distribution reconstructed using the super-concentrated electrode configuration demonstrated the highest correlation (R = 0.98; p < 0.01) with the original epicardial source model. A mean localization error of 5.3 mm was found in the pacemaker patients. CONCLUSION: This study demonstrated the feasibility of deriving detailed anterior epicardial potential information using only 62 torso electrodes without the use of an a priori model.
No takes yet. Share an insight, caveat, or question.
Graaf et al. (2015) studied Structurally normal heart (healthy volunteers and pacemaker patients) (n=7). Super-concentrated 62-electrode configuration for inverse potential mapping vs. Other electrode configurations (e.g., 252 electrodes or 62 electrodes surrounding thorax) was evaluated on Correlation with epicardial source model (R = 0.98, p=<0.01). A super-concentrated 62-electrode configuration for inverse potential mapping without an a priori model achieved a high correlation with the epicardial source model and a mean in vivo localization error of 5.3 mm.
Synapse has enriched 10 related papers. Consider them for comparative context: