Answers are grounded in this paper and cite their sources.
Only time will tell if it was time well spent. —Jimmy Buffett The quest for simplified surgical techniques to be used in cases without appropriate capsular support brought the creation of flanges to the forefront as flanged techniques do not require scleral flaps, sutures, or knots. Flanges are nail head–like ends of intraocular lens (IOL) haptics or polypropylene sutures created using low temperature cautery. As originally described in a 2017 publication, the Yamane technique involves use of a 3-piece IOL, which is injected into the anterior chamber with the trailing haptic kept outside of the eye to prevent IOL posterior dislocation.1 An angled sclerotomy is made through the conjunctiva with a 30-gauge thin-walled needle at 2.0 mm from the limbus. The leading haptic of the lens is threaded into the lumen of the needle with forceps. A second sclerotomy is then made 180 degrees from the first one, and the trailing haptic is inserted into the lumen of the second needle, whereas the first needle is placed on the eyelid. Both haptics are then externalized onto the conjunctiva (double-needle technique). The ends of the haptics are cauterized to make a flange with a diameter of 0.3 mm, which is pushed back and fixated into the scleral tunnels. Although different 3-piece IOLs have been used in different studies, an IOL that has been particularly suitable in this application is the CT Lucia 602 (Carl Zeiss Meditec, formerly EC-3 PAL, Aaren Scientific), on account of robust haptics made of polyvinylidene fluoride, resistant to deformation and breakage. Since publication of the original technique, there have been modifications to it, which were particularly related to the haptic-needle docking, considered to be a technically challenging step. The aim of the modifications was generally to optimize the positional relationship between the IOL haptic and the injection needle during docking.2,3 Inspired by the Yamane technique, Canabrava et al. introduced a double-flanged polypropylene technique to stabilize the capsular bag in the setting of zonular weakness, initially using a polypropylene haptic removed from a 3-piece IOL and later using an adjustable 5-0 polypropylene suture.4,5 In this technique, a flange is created in one of the extremities of the 5-0 polypropylene monofilament. The other extremity is introduced into the suturing eyelet of a capsular tension segment, and the device is placed into the capsular bag and aligned with the weakest zonular quadrant. A 26-gauge needle guides the externalization of the free monofilament extremity through a sclerotomy made transconjunctivally approximately 2.0 mm from the limbus, and a flange is created on this extremity, allowing intrascleral fixation of the capsular tension segment. Later, a 4-flanged technique was described for intrascleral fixation of a 1-piece poly(methyl methacrylate) IOL with eyelets in the loops, which is secured by 2 flanges in the eyelets and 2 flanges inserted into scleral tunnels 2.0 mm from the limbus.6 Canabrava et al. recently proposed a modification of their 4-flange technique using 6-0 polypropylene sutures and foldable 1-piece, plate-type IOLs with 4 closed loops, such as the Akreos AO60 lens (Bausch & Lomb, Inc.).7 Each suture is passed through the 2 closed loops on each side of the lens, and all 4 suture extremities are externalized with flanges created and buried into scleral tunnels. In the original description, the IOL was folded and inserted with forceps through a 3.4 mm corneal incision. This issue features 2 Technique articles on flanges, by Mahler et al. (page 1227) and Menna Barreto et al. (page 1234). Mahler et al. describe a modification of the IOL insertion method in the 4-flanged IOL fixation technique. An Akreos AO60 IOL was inserted into the eye through a standard 2.4 mm corneal incision by using its designated cartridge and injector without the need to enlarge the primary incision. Mahler et al. have used an intrascleral 4-flanged technique for the management of in-the-bag IOL subluxation in a previous study.8 Modified adjustable flange intrascleral fixation techniques by Assia and Wong using 6-0 polypropylene sutures have been recently used in scleral fixation of a variety of IOLs, including hydrophilic acrylic, hydrophobic acrylic, and poly(methyl methacrylate) aniridic IOLs, and in the capsular anchor to stabilize the capsular bag in eyes with compromised zonular fibers.9 The same authors have also applied these techniques in the repositioning of subluxated in-the-bag IOLs.10 An important point that is common among sutureless intrascleral fixation methods in general is to appropriately bury the haptics (eg, in the glued IOL technique) or flanges within the sclera and ultimately avoid exposure through the conjunctiva, eliminating any entry port for surrounding flora pathogens that could increase the risk for endophthalmitis.11,12 Technical aspects that are frequently highlighted by Canabrava et al. to avoid this complication are related to the size of the flange and the length of the scleral tunnel created with the needle before entering the eye. A flange that is too large may remain outside of the scleral tunnel and erode through the conjunctiva. A long intrascleral tunnel should be created. Another important step to prevent flange exposure is to increase the tension of the polypropylene suture by holding its base with microforceps in close apposition to the sclera. The suture should be cut 2.0 mm from the microforceps for the creation of the flange, which is then buried into the sclera.12 Furthermore, the entry point in the conjunctiva should not be directly above the entry point in the sclera. Instead, the conjunctive needs to be slightly shifted before the insertion of the needle.9,10 Of the initial 7 patients operated on with the 4-flanged technique, Canabrava et al. encountered flange erosion in 1 patient, 1 month postoperatively.7 One of the flanges was too large and was found to be outside of the scleral tunnel. Subsequently, the eye developed hyperemia and conjunctival inflammation and degradation. Besides appropriate medical treatment, the size of the flange was surgically reduced, followed by reinsertion inside of the scleral tunnel. Another case was recently reported with a flange that was exposed above the conjunctiva, being successfully managed with cutting of the redundant suture length and creation of a smaller flange that was then reinserted into the tunnel.12 Assia and Wong encountered flange extrusion after using their modified flanged technique to reposition an in-the-bag subluxated open-loop IOL in a 100-year-old patient.10 One of the flanges was seen extruding through the conjunctiva early postoperatively, but the patient refused further surgery. Seven months later, the eye developed streptococcal infection, which responded to aggressive intravitreal antibiotic regimen. A case of endophthalmitis related to an exposed flange after performance of the 4-flanged sutureless intrascleral IOL fixation of Canabrava et al. was published recently.13 It involved a 101-year-old woman who underwent surgery using this technique in her left eye 6 months prior to her presentation with pain and loss of vision for the previous 4 days. Visual acuity was of hand motion, and signs included conjunctival hyperemia, corneal edema, hypopyon, vitritis, and 2 temporal polypropylene flanges exposed through the conjunctiva, whereas the 2 other flanges were covered by conjunctiva at the nasal side. The infection resolved within a few weeks with medical treatment, including intravitreal injections of antibiotics/steroids; however, the patient declined any further procedures, and phthisis bulbi developed subsequently. The abovementioned cases were related to flange erosion or exposure observed up to 6 months postoperatively. It is important to keep in mind that each extraocular flange in theory carries a risk for erosion/extrusion, therefore increasing the risk for endophthalmitis. Because flanged techniques are relatively new, surgeons should be aware of the appropriate steps for flange creation and coverage and management of flange erosion/exposure when observed. This complication may be observed later postoperatively, and long-term surveillance is warranted. We have been witnessing the unfolding of a new era, with increasing popularity and expansion of the use of flanges in anterior segment surgery. It is hoped that they will stand the test of time…!
No takes yet. Share an insight, caveat, or question.
Liliana Werner (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: