Key result
A single-point fingertip pulse monitoring strategy using a flexible iontronic pressure sensor demonstrated accuracy comparable to existing clinical criteria for evaluating arteriosclerosis.
Why the study?
Clinical PWV measurement typically requires bulky equipment and skilled operators, while wearable two-point photoplethysmographic sensors remain prone to natural light interference.
Does single-point fingertip pulse monitoring using a flexible iontronic pressure sensor accurately evaluate arteriosclerosis compared to existing clinical criteria?
Observational
Does single-point fingertip pulse monitoring using a flexible iontronic pressure sensor accurately evaluate arteriosclerosis compared to existing clinical criteria?
A novel wearable iontronic sensor for single-point fingertip pulse monitoring provides a reliable and accurate method for assessing arteriosclerosis via pulse wave velocity.
Answers are grounded in this paper and cite their sources.
May enable single-point wearable PWV monitoring; leaves open prospective validation before clinical adoption.
Arteriosclerosis, which appears as a hardened and narrowed artery with plaque buildup, is the primary cause of various cardiovascular diseases such as stroke. Arteriosclerosis is often evaluated by clinically measuring the pulse wave velocity (PWV) using a two-point approach that requires bulky medical equipment and a skilled operator. Although wearable photoplethysmographic sensors for PWV monitoring are developed in recent years, likewise, this technique is often based on two-point measurement, and the signal can easily be interfered with by natural light. Herein, a single-point strategy is reported based on stable fingertip pulse monitoring using a flexible iontronic pressure sensor for heart-fingertip PWV (hfPWV) measurement. The iontronic sensor exhibits a high pressure-resolution on the order of 0.1 Pa over a wide linearity range, allowing the capture of characteristic peaks of fingertip pulse waves. The forward and reflected waves of the pulse are extracted and the time difference between the two waves is computed for hfPWV measurement using Hiroshi's method. Furthermore, a hfPWV-based model is established for arteriosclerosis evaluation with an accuracy comparable to that of existing clinical criteria, and the validity of the model is verified clinically. The work provides a reliable technique that can be used in wearable arteriosclerosis assessment systems.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2023) conducted an observational in Arteriosclerosis. Single-point fingertip pulse monitoring using a flexible iontronic pressure sensor vs. Existing clinical criteria was evaluated on Arteriosclerosis evaluation (heart-fingertip pulse wave velocity). A single-point fingertip pulse monitoring strategy using a flexible iontronic pressure sensor demonstrated accuracy comparable to existing clinical criteria for evaluating arteriosclerosis.
Synapse has enriched 10 related papers. Consider them for comparative context: